CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT

被引:13
作者
Christe, Andreas [1 ,2 ]
Lin, Margaret C. [2 ]
Yen, Andrew C. [2 ]
Hallett, Rich L. [2 ]
Roychoudhury, Kingshuk [3 ]
Schmitzberger, Florian [2 ]
Fleischmann, Dominik [2 ]
Leung, Ann N. [2 ]
Rubin, Geoffry D. [2 ]
Vock, Peter [1 ]
Roos, Justus E. [2 ]
机构
[1] Univ Hosp Bern, Univ Inst Diagnost Intervent & Pediat Radiol, Inselspital, CH-3010 Bern, Switzerland
[2] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[3] Natl Univ Ireland Univ Coll Cork, Dept Stat, Cork, Ireland
基金
瑞士国家科学基金会;
关键词
Low-dose thoracic CT; CT patterns; Fungal pulmonary infection; Radiation dose reduction; FOLLOW-UP; EARLY DIAGNOSIS; IMAGE QUALITY; NODULES; CANCER; ASPERGILLOSIS; MANAGEMENT; THORAX; SCANS;
D O I
10.1016/j.ejrad.2011.06.059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients. Materials and methods: Raw data of thoracic CT scans (64 x 0.75 mm, 120 kVp, 300 reference mAs) from 41 consecutive patients with clinical suspicion of pulmonary fungal infection were collected. In 32 patients fungal infection could be proven (median age of 55.5 years, range 35-83). A total of 267 cuboids showing CT patterns of fungal infection and 27 cubes having no disease were reconstructed at the original and 6 simulated tube currents of 100, 40, 30, 20, 10, and 5 reference mAs. Eight specific fungal CT patterns were analyzed by three radiologists: 76 ground glass opacities, 42 ground glass nodules, 51 mixed, part solid, part ground glass nodules, 36 solid nodules, 5 lobulated nodules, 6 spiculated nodules, 14 cavitary nodules, and 37 foci of air-space disease. The standard of reference was a consensus subjective interpretation by experts whom were not readers in the study. Results: The mean sensitivity and standard deviation for detecting pathological cuboids/disease using standard dose CT was 0.91 + 0.07. Decreasing dose did not affect sensitivity significantly until the lowest dose level of 5 mAs (0.87 +/- 0.10, p = 0.012). Nodular pattern discrimination was impaired below the dose level of 30 reference mAs: specificity for fungal 'mixed nodules' decreased significantly at 20, 10 and 5 reference mAs (p < 0.05). At lower dose levels, classification drifted from 'solid' to 'mixed nodule', although no lesion was missed. Conclusion: Our simulation data suggest that tube current levels can be reduced from 300 to 30 reference mAs without impairing the diagnostic information of specific CT patterns of pulmonary fungal infections. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2860 / 2866
页数:7
相关论文
共 20 条
[1]   The Lung Image Database Consortium (LIDC): An evaluation of radiologist variability in the identification of lung nodules on CT scans [J].
Armato, Samuel G., III ;
McNitt-Gray, Michael F. ;
Reeves, Anthony P. ;
Meyer, Charles R. ;
McLennan, Geoffrey ;
Aberle, Denise R. ;
Kazerooni, Ella A. ;
MacMahon, Heber ;
van Beek, Edwin J. R. ;
Yankelevitz, David ;
Hoffman, Eric A. ;
Henschke, Claudia I. ;
Roberts, Rachael Y. ;
Brown, Matthew S. ;
Engelmann, Roger M. ;
Pais, Richard C. ;
Piker, Christopher W. ;
Qing, David ;
Kocherginsky, Masha ;
Croft, Barbara Y. ;
Clarke, Laurence P. .
ACADEMIC RADIOLOGY, 2007, 14 (11) :1409-1421
[2]   Defining opportunistic invasive fungal infections in immunocompromised patients with cancer and hematopoietic stem cell transplants: An international consensus [J].
Ascioglu, S ;
Rex, JH ;
de Pauw, B ;
Bennett, JE ;
Bille, J ;
Crokaert, F ;
Denning, DW ;
Donnelly, JP ;
Edwards, JE ;
Erjavec, Z ;
Fiere, D ;
Lortholary, O ;
Maertens, J ;
Meis, JF ;
Patterson, TF ;
Ritter, J ;
Selleslag, D ;
Shah, PM ;
Stevens, DA ;
Walsh, TJ .
CLINICAL INFECTIOUS DISEASES, 2002, 34 (01) :7-14
[3]   Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques [J].
Bankier, Alexander A. ;
Schaefer-Prokop, Cornelia ;
De Maertelaer, Viviane ;
Tack, Denis ;
Jaksch, Peter ;
Klepetko, Walter ;
Gevenois, Pierre Alain .
RADIOLOGY, 2007, 242 (03) :898-906
[4]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[5]   Low-dose multislice CT of the thorax in follow-up of malignant lymphoma and extrapulmonary primary tumors [J].
Dinkel, HP ;
Sonnenschein, M ;
Hoppe, H ;
Vock, P .
EUROPEAN RADIOLOGY, 2003, 13 (06) :1241-1249
[6]  
Fleiss J.L., 1981, Statistical methods for rates and proportions, V2nd, P38
[7]  
FLEISS JL, 1971, PSYCHOL BULL, V76, P378, DOI 10.1037/h0031619
[8]   Lung nodule detection with ultra-low-dose CT in routine follow-up of cancer patients [J].
Gergely, I ;
Neumann, C ;
Reiger, F ;
Dorffner, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (08) :1077-1083
[9]   Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules [J].
Karabulut, N ;
Törü, M ;
Gelebek, V ;
Gülsün, M ;
Ariyurek, OM .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2764-2769
[10]   INVASIVE PULMONARY ASPERGILLOSIS IN ACUTE-LEUKEMIA - THE CONTRIBUTION OF CT TO EARLY DIAGNOSIS AND AGGRESSIVE MANAGEMENT [J].
KUHLMAN, JE ;
FISHMAN, EK ;
BURCH, PA ;
KARP, JE ;
ZERHOUNI, EA ;
SIEGELMAN, SS .
CHEST, 1987, 92 (01) :95-99