Determination of sub-ppb cadmium in urine by solid-phase extraction and inductively coupled plasma-mass spectrometry

被引:30
作者
Suzuki, Yoshihiro [1 ]
Endo, Yoko [1 ]
Ogawa, Masanori [1 ]
Matsuda, Michiko [1 ]
Nakajima, Yoshiaki [1 ]
Onda, Nobuhiko [1 ]
Iwasaki, Motoki [2 ]
Tsugane, Shoichiro [2 ]
机构
[1] Tokyo Rosai Occupat Dis & Injuries Hosp, Japan Labour Hlth & Welfare Org, Res Ctr Occupat Poisoning, Tokyo 1430013, Japan
[2] Natl Canc Ctr, Res Ctr Canc Prevent & Screening, Epidemiol & Prevent Div, Tokyo 1040045, Japan
关键词
D O I
10.2116/analsci.24.1049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to determine low levels of Cd in urine samples, we tried to remove Mo interference using ICP-MS with a dynamic reaction-cell technique, but failed due to the low sensitivity and the variance with the standards. We then performed solid-phase extraction (SPE) before the ICP-MS measurement. A commercially available chelating resin, NOBIAS PA-1, was used for SPE, and could effectively remove Mo from urine samples, permitting the accurate determination of Cd by ICP-MS. This SPE-ICP-MS method gave 0.012 mu g Cd L-1 as the method limit of quantification, and the mean recovery of Cd spiked with 0.0505 and 5.05 mu g L-1 was 93.1 and 97.6%, respectively.
引用
收藏
页码:1049 / 1052
页数:4
相关论文
共 17 条
[1]  
*CDCP, 2005, 3 NAT REP HUM EXP EN
[2]   Bandpass reaction cell inductively coupled plasma mass spectrometry for the determination of silver and cadmium in samples in the presence of excess Zr, Nb and Mo [J].
Chang, CC ;
Liu, HT ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 2003, 493 (02) :213-218
[3]   Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood [J].
de Boer, JLM ;
Ritsema, R ;
Piso, S ;
van Staden, H ;
van den Beld, W .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (5-6) :872-880
[4]   SI-traceable certification of the amount content of cadmium below the ng g-1 level in blood samples by isotope dilution ICP-MS applied as a primary method of measurement [J].
Diemer, J ;
Vogl, J ;
Quétel, CR ;
Linsinger, T ;
Taylor, PDP ;
Lamberty, A ;
Pauwels, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :492-498
[5]   No clear-cut evidence for cadmium-induced renal tubular dysfunction among over 10,000 women in the Japanese general population: a nationwide large-scale survey [J].
Ezaki, T ;
Tsukahara, T ;
Moriguchi, J ;
Furuki, K ;
Fukui, Y ;
Ukai, H ;
Okamoto, S ;
Sakurai, H ;
Honda, S ;
Ikeda, M .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2003, 76 (03) :186-196
[6]   Development of column-pretreatment chelating resins for matrix elimination/multi-element determination by inductively coupled plasma-mass spectrometry [J].
Gao, YH ;
Oshita, K ;
Lee, KH ;
Oshima, M ;
Motomizu, S .
ANALYST, 2002, 127 (12) :1713-1719
[7]  
HORICK G, 1998, INDUCTIVELY COUPLED, P543
[8]  
INAGAKI K, 2001, ANAL SCI, V17, P991
[9]  
*JAP IND STAND, 2006, JIS HDB, V53, P371
[10]   Inductively coupled plasma mass spectrometric determination of molybdenum in urine [J].
Minoia, C ;
Gatti, A ;
Aprea, C ;
Ronchi, A ;
Sciarra, G ;
Turci, R ;
Bettinelli, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (13) :1313-1319