Once-Weekly Transdermal Buprenorphine Application Results in Sustained and Consistent Steady-State Plasma Levels

被引:38
作者
Kapil, Ram P. [1 ]
Cipriano, Alessandra [1 ]
Friedman, Kristen [1 ]
Michels, Gregory [1 ]
Shet, Manjunath S. [1 ]
Colucci, Salvatore V. [1 ]
Apseloff, Glen [2 ]
Kitzmiller, Joseph [2 ]
Harris, Stephen C. [1 ]
机构
[1] Purdue Pharma LP, Stamford, CT 06901 USA
[2] Ohio State Univ, Columbus, OH 43210 USA
关键词
Buprenorphine pharmacokinetics; consistent and sustained delivery of buprenorphine; analgesia; patch; pain management; randomized trials; seven-day transdermal delivery; once-weekly; LOW-BACK-PAIN; DOUBLE-BLIND; INTRAVENOUS BUPRENORPHINE; RETROSPECTIVE COHORT; ANALGESIC EFFICACY; CLINICAL-PRACTICE; OPIOID THERAPY; CANCER PAIN; SYSTEM; MANAGEMENT;
D O I
10.1016/j.jpainsymman.2012.06.014
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Context. Transdermal formulations of buprenorphine offer controlled delivery of buprenorphine for sustained analgesic efficacy with reduced adverse events (AEs) compared with the other modes of administration. A buprenorphine transdermal system (BTDS) delivering 5, 10, or 20 mcg/hour for seven days is now marketed in the U.S. as Butrans (R) (Lohmann Therapie-System AG, Andernach Germany), a Schedule III single-entity opioid analgesic indicated for the management of moderate and chronic pain in patients requiring continuous around-the-clock analgesia for an extended period. Objectives. This was a randomized open-label study in healthy subjects to characterize the steady-state buprenorphine pharmacokinetics after the delivery of three consecutive seven-day BTDS applications. Methods. Thirty-seven subjects were randomized to receive three consecutive BTDS 10 mcg/hour (BTDS 10) patches applied to the deltoid or upper back for seven days each. Blood samples for buprenorphine concentration measurements were taken. Safety was assessed using recorded AEs, clinical laboratory test results, vital signs, pulse oximetry, physical examinations, and electrocardiograms. Patch adhesion assessments were taken. Results. Analysis of C-min demonstrated that steady state was reached during the first BTDS 10 application. No significant difference in C-min was observed across the three applications. Total and peak plasma buprenorphine exposures were similar after each of the seven-day administrations of BTDS. Conclusion. Three consecutive once-weekly applications of BTDS 10 provided consistent and sustained delivery of buprenorphine. Steady-state plasma concentrations were reached within 48 hours of the first application of BTDS 10. Patch adhesion analysis confirmed the appropriateness of the seven-day application period. Overall, BTDS 10 was safe and well tolerated. (c) 2013 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 53 条
  • [1] [Anonymous], 2006, SUB FULL PRESCR INF
  • [2] [Anonymous], 2011, BUTR FULL PRESCR INF
  • [3] [Anonymous], 2005, BUPR FULL PRESCR INF
  • [4] Aurilio C, 2005, MINERVA ANESTESIOL, V71, P445
  • [5] TRANSCUTANEOUS DRUG-DELIVERY - A PRACTICAL REVIEW
    BERTI, JJ
    LIPSKY, JJ
    [J]. MAYO CLINIC PROCEEDINGS, 1995, 70 (06) : 581 - 586
  • [6] Buprenorphine in a transdermal therapeutic system -: A new option
    Böhme, K
    [J]. CLINICAL RHEUMATOLOGY, 2002, 21 (Suppl 1) : S13 - S16
  • [7] Bonnet F, 2009, CURR MED RES OPIN, V25, P293, DOI [10.1185/03007990802631321, 10.1185/03007990802631321 ]
  • [8] Budd K, 2003, INT J CLIN PRACT, P9
  • [9] Editorial III. Old dog - new(ma)trix
    Budd, K
    Collett, BJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (06) : 722 - 724
  • [10] SUB-LINGUAL BUPRENORPHINE USED POSTOPERATIVELY - 10-HOUR PLASMA DRUG CONCENTRATION ANALYSIS
    BULLINGHAM, RES
    MCQUAY, HJ
    PORTER, EJB
    ALLEN, MC
    MOORE, RA
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 13 (05) : 665 - 673