Long-term durability prediction models for GFRP bars in concrete environment

被引:180
作者
Davalos, Julio F. [2 ]
Chen, Yi [1 ]
Ray, Indrajit [2 ]
机构
[1] SWSG PC, Reston, VA 20190 USA
[2] W Virginia Univ, Dept Civil & Environm Engn, Ctr Transportat Secur & Infrastruct Innovat TranS, Morgantown, WV 26506 USA
关键词
Ageing; bars; durability; fiber reinforced polymers; glass fiber; prediction model; REINFORCING BARS; FRP; PERFORMANCE; DEGRADATION;
D O I
10.1177/0021998311427777
中图分类号
TB33 [复合材料];
学科分类号
摘要
This article presents a durability study of glass fiber reinforced polymer (GFRP) bars within concrete environment and provides recommendations for effective accelerated ageing methods, data reduction and validation, and formulation of master curves for long-term predictions. Concrete beams reinforced with GFRP bars were immersed in tap water inside temperature-controlled tanks. Sustained load was applied to beam samples, and elevated temperatures were used to accelerate the ageing of GFRP bars. After exposure, GFRP bars were tested for residual tensile strength, which was considered as a measure of the durability performance of the specimens. Scanning electron microscopy (SEM) images were used to evaluate the microstructural changes of conditioned specimens. Short-term (up to 270 days) results showed that compared to alkalinity and low sustained load, moisture and elevated temperature played much more important roles in accelerating environmental attack to GFRP bars. Based on the short-term test results, the dominant degradation mechanism for GFRP bars in concrete was found as the deterioration of fiber/matrix interface. A degradation model based on Arrhenius concept and prediction procedures are given, and correlations with other studies and field data are provided. The tensile strength retentions for GFRP bars in saturated concrete subjected to sustained load were predicted. It was found that degradation rates decreased rapidly, but tensile strength retentions at different exposure temperatures converge to a constant value with the increase of exposure time. Beyond fiber-matrix debonding, there is a possibility that other degradation mechanisms such as fiber corrosion may start to dominate the deterioration process of GFRP bars with time.
引用
收藏
页码:1899 / 1914
页数:16
相关论文
共 24 条
[1]  
ACI, 2006, ACI 440.1R-06
[2]   Durability of GFRP rebars in concrete beams under sustained loads at severe environments [J].
Almusallam, TH ;
Al-Salloum, YA .
JOURNAL OF COMPOSITE MATERIALS, 2006, 40 (07) :623-637
[3]  
[Anonymous], 2000, ANN BOOK ASTM STAND
[4]  
Bakis CE, 1998, J COMPOS TECH RES, V20, P29
[5]   A model specification for FRP composites for civil engineering structures [J].
Bank, LC ;
Gentry, TR ;
Thompson, BP ;
Russell, JS .
CONSTRUCTION AND BUILDING MATERIALS, 2003, 17 (6-7) :405-437
[6]  
Bank LC, 1998, ACI MATER J, V95, P232
[7]  
Beddow J., 2002, P 9TH INT C FIB REIN, P215
[8]   Durability of FRP in concrete - deterioration mechanisms [J].
Byars, EA ;
Waldron, P ;
Dejke, V ;
Demis, S ;
Heddadin, S .
INTERNATIONAL JOURNAL OF MATERIALS & PRODUCT TECHNOLOGY, 2003, 19 (1-2) :28-39
[9]  
CACERES A, 2000, SP2091SHR NAV FAC EN
[10]  
Chen Y, 2007, P 8 INT S FIB REINF