Interleukin-8 secretion from monocytic cell lines for evaluation of the inflammatory potential of organic dust

被引:21
作者
Allermann, L [1 ]
Poulsen, OM [1 ]
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
关键词
IL-8; monocytes; dust; endotoxin; indoor air;
D O I
10.1006/enrs.2002.4335
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The potential of organic dust to induce inflammation in vitro can be viewed as a crude measure of the total biologically active compounds in a dust sample. The purpose of this study was to further develop an in vitro screening method for evaluation of potential hazard related to low doses of dust exposure using two monocytic cell lines (U937 and THP-1). Dust was obtained from schools in Copenhagen. U937 and THP-1 cells were stimulated with dust for 24 h and interleukin-8 secretion was measured. The initial slopes of the dose-response curves were used to calculate the inflammatory potential, or potency factor (PF), of the samples. In characterization of the method, lipopolysaccharide from Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Salmonella enteritidis were tested together with three glucans, nickel sulfate (NiSO4), methyl methacrylate (MMA), formaldehyde, and four surfactants. The PF values of LPSs in both monocytic assays ranked as follows: S. enteritidis> E. coli> K pneumoniae> P. aeruginosa. The PF values of NiSO4 MMA, formaldehyde, and the surfactants were zero or below. Using the THP-1 cell line, the PF values of dust samples were 30 times higher than when using the U937 cell line, and 7 times higher than when using the lung epithelial cell line (A549). The high sensitivity of the THP-1 bioassay makes it potentially useful as a screening tool for hazard evaluation of dust from, e.g., the indoor environment. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:188 / 198
页数:11
相关论文
共 44 条
[1]  
ADACHI Y, 1994, BIOL PHARM BULL, V17, P1554, DOI 10.1248/bpb.17.1554
[2]   Inflammatory potential of dust from waste handling facilities measured as IL-8 secretion from lung epithelial cells in vitro [J].
Allermann, L ;
Poulsen, OM .
ANNALS OF OCCUPATIONAL HYGIENE, 2000, 44 (04) :259-269
[3]  
ALLERMANN L, 2001, THESIS NATL I OCCUPA, P1
[4]  
ALLERMANN L, 1999, INDOOR AIR, V2, P719
[5]  
*ASTM, 1994, ANN BOOK ASTM STAND, P570
[6]  
CHANYEUNG M, 1994, ORGANIC DUST EXPOSUR, P3
[7]   PROTOCOL FOR THE DESIGN AND INTERPRETATION OF METHOD EVALUATION IN ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS - APPLICATION TO THE DETERMINATION OF LEAD AND MANGANESE IN BLOOD [J].
CHRISTENSEN, JM ;
POULSEN, OM ;
ANGLOV, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :329-334
[8]   APPLICATION OF A NEW AMIQAS COMPUTER-PROGRAM FOR INTEGRATED QUALITY-CONTROL, METHOD EVALUATION AND PROFICIENCY TESTING [J].
CHRISTENSEN, SL ;
ANGLOV, JTB ;
CHRISTENSEN, JM ;
OLSEN, E ;
POULSEN, OM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4) :343-350
[9]   (1-]3)-BETA-D-GLUCAN IN INDOOR AIR, ITS MEASUREMENT AND IN-VITRO ACTIVITY [J].
GOTO, H ;
YUASA, K ;
RYLANDER, R .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1994, 25 (01) :81-83
[10]  
HANSEN AM, 1991, ANN OCCUP HYG, V35, P603