Portable Device for the Measurement and Assessment of the Human Equilibrium

被引:4
作者
Estevez-Pedraza, Angel Gabriel [1 ]
Martinez-Mendez, Rigoberto [1 ]
Portillo-Rodriguez, Otniel [1 ]
Parra-Rodriguez, Lorena [2 ]
机构
[1] Autonomous Univ State Mexico, Fac Engn, Cerro Coatepec S-N, Toluca, Mexico
[2] Natl Inst Geriatr, Gerontotechnol Dept, Anillo Perifer 2767, Mexico City, DF, Mexico
关键词
Center of pressure; Balance in older adults; Electronic system; WII BALANCE BOARD; POSTURAL BALANCE; FORCE; PARAMETERS;
D O I
10.1007/s10439-020-02630-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work presents the design and development of a new alternative tool to measure the Center of Pressure (CoP) displacements, intended to evaluate the human balance. The device is based on a modified commercial balance board used for video games, resulting in a low-cost, portable device capable of computing the CoP, providing 24 of the most used indexes to test the human balance. The proposed standalone device runs on rechargeable batteries, weighs only 3.5 kg, and has a data storage capacity for over 1000 tests. Visual and auditory instructions assist its user interface. Thus, contrary to the commercial systems designed for laboratory use, this device enables the measurement of quantitative balance parameters in non-laboratory places, allowing the study of the balance of vulnerable populations directly on their typical environments. To evaluate the device, 20 older adults (68.60 +/- 1.23 years) were tested, and the resulting values were compared with a similar study using a force platform; 19 indexes showed a similarity with those reported using force platform and 12 of these were statistically equivalent. The proposed device represents an open-source alternative tool for researchers and healthcare personnel to acquire reliable data to evaluate human balance.
引用
收藏
页码:933 / 945
页数:13
相关论文
共 42 条
[31]  
Perry J., 1993, Dev. Med. Child Neurol., V35, P1122
[32]   Measures of postural steadiness: Differences between healthy young and elderly adults [J].
Prieto, TE ;
Myklebust, JB ;
Hoffmann, RG ;
Lovett, EG ;
Myklebust, BM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (09) :956-966
[33]   Identification of distinct characteristics of postural sway in Parkinson's disease: A feature selection procedure based on principal component analysis [J].
Rocchi, L ;
Chiari, L ;
Cappello, A ;
Horak, FB .
NEUROSCIENCE LETTERS, 2006, 394 (02) :140-145
[34]  
Rodgers M, 2004, 28 ANN M AM SOC BIOM
[35]   Clinical stabilometry standardization Basic definitions - Acquisition interval - Sampling frequency [J].
Scoppa, Fabio ;
Capra, Roberto ;
Gallamini, Michele ;
Shiffer, Riccardo .
GAIT & POSTURE, 2013, 37 (02) :290-292
[36]  
Sezer O, 2005, 48 MIDW S CIRC SYST, DOI [10.1109/MWSCAS.2005.1594146, DOI 10.1109/MWSCAS.2005.1594146]
[37]   Validity Analysis of Wii Balance Board Versus Baropodometer Platform Using an Open Custom Integrated Application [J].
Sgro, Francesco ;
Monteleone, Giuseppe ;
Pavone, Marica ;
Lipoma, Mario .
2014 AASRI CONFERENCE ON SPORTS ENGINEERING AND COMPUTER SCIENCE (SECS 2014), 2014, 8 :22-29
[38]  
Shu Lin, 2012, 2012 International Conference on Computerized Healthcare (ICCH), P91, DOI 10.1109/ICCH.2012.6724478
[39]   Clinical and biomechanical measures of balance as fall predictors in ambulatory nursing home residents [J].
Thapa, PB ;
Gideon, P ;
Brockman, KG ;
Fought, RL ;
Ray, WA .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 1996, 51 (05) :M239-M246
[40]   Use of the Nintendo Wii Balance Board for Studying Standing Static Balance Control:Technical Considerations, Force-Plate Congruency, and the Effect of Battery Life [J].
Weaver, Tyler B. ;
Ma, Christine ;
Laing, Andrew C. .
JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (01) :48-55