Simplified Stereo-Optical Ultrasound Plane Calibration

被引:2
作者
Hossbach, Martin [1 ]
Noll, Matthias [1 ]
Wesarg, Stefan [1 ]
机构
[1] Fraunhofer IGD, Competence Ctr Cognit Comp & Med Imaging, D-64283 Darmstadt, Germany
来源
MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY | 2013年 / 8675卷
关键词
Calibration; Ultrasound; Needle Guidance; Tracking;
D O I
10.1117/12.2006744
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing different calibration objects: a 6 mm metal bar and a 1.25 mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity.
引用
收藏
页数:7
相关论文
共 8 条
[1]  
[Anonymous], 2000, Multiple View Geometry in Computer Vision
[2]   Freehand Versus Guided Breast Biopsy: Comparison of Accuracy, Needle Motion, and Biopsy Time in a Tissue Model [J].
Bluvol, Nathan ;
Kornecki, Anat ;
Shaikh, Allison ;
Fernandez, David Del Rey ;
Taves, Donald H. ;
Fenster, Aaron .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) :1720-1725
[3]   An in-vitro study to understand successful free-hand ultrasound guided intervention [J].
Bradley, MJ .
CLINICAL RADIOLOGY, 2001, 56 (06) :495-498
[4]  
Bruder R., 2011, BILDVERARBEITUNG MED, P179
[5]   A needle tracking device for ultrasound guided percutaneous procedures [J].
Chan, C ;
Lam, F ;
Rohling, R .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11) :1469-1483
[6]  
KHOSRAVI S, 2007, IEEE T MED IMAGING, P2251
[7]   One-step needle pose estimation for ultrasound guided biopsies [J].
Khosravi, Sara ;
Rohling, Robert ;
Lawrence, Peter .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :3343-3346
[8]  
ZHANG H, 2006, P SOC PHOTO-OPT INS, V6141, P775