In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound
被引:7
|作者:
Kim, Soo-Joong
[1
,2
]
Lee, Hang
[3
]
Kato, Koji
[1
]
Yonetsu, Taishi
[1
]
Jang, Ik-Kyung
[1
]
机构:
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA 02115 USA
[2] Kyung Hee Univ, Div Cardiol, Coll Med, Seoul, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Biostat, Boston, MA USA
来源:
关键词:
Time domain;
Frequency domain;
Optical coherence tomography;
Intravascular ultrasound;
CORONARY-ARTERIES;
ANGIOGRAPHY;
VALIDATION;
CATHETER;
DISEASE;
SYSTEM;
D O I:
10.1007/s10554-012-0179-1
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Lumen dimensions measured by time-domain optical coherence tomography (TD-OCT) may be influenced by the hemodynamic effect of proximal balloon occlusion. Frequency-domain OCT (FD-OCT) does not require the interruption of blood flow. Therefore, we compared the coronary lumen dimensions measured by TD-OCT, FD-OCT, and intravascular ultrasound (IVUS) in both stented and non-stented segments. Twenty patients who underwent both IVUS and OCT imaging (10 for TD- and 10 for FD-OCT) after stent implantation were included. The maximum, minimum, and mean diameters and areas were measured at the proximal and distal stent edges, as well as 3 mm inside and 5 mm outside of both edges. The measurements inside stent showed no significant differences between IVUS and TD- or FD-OCT. The lumen mean diameters and areas measured by IVUS at 5 mm outside stent were similar to those measured by FD-OCT (Distal; 3.07 +/- A 0.7 vs 3.03 +/- A 0.7 mm, p = 0.08 and 7.80 +/- A 4.0 vs 7.72 +/- A 4.1 mm(2), p = 0.07, respectively. Proximal; 3.25 +/- A 0.7 vs 3.23 +/- A 0.7 mm, p = 0.09 and 8.78 +/- A 3.8 vs 8.65 +/- A 3.7 mm(2), p = 0.08, respectively), but were greater than those measured by TD-OCT (Distal; 2.75 +/- A 0.5 vs 2.29 +/- A 0.5 mm, p = 0.0001 and 6.15 +/- A 2.6 vs 4.38 +/- A 1.9 mm(2), p = 0.0002, respectively. Proximal; 3.27 +/- A 0.6 vs 2.69 +/- A 0.6 mm, p = 0.0001 and 8.64 +/- A 3.4 vs 6.12 +/- A 2.7 mm(2), p = 0.0001 respectively). The interaction between TD- and FD-OCT for lumen dimension measurements at 5 mm outside stent was statistically significant. Vessel dimension measurements were similar between IVUS and FD-OCT in native vessel unlike with TD-OCT. Therefore, we might adapt the IVUS criteria of lesion severity for percutaneous coronary intervention to FD-OCT.
引用
收藏
页码:967 / 975
页数:9
相关论文