In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound

被引:9
作者
Kim, Soo-Joong [1 ,2 ]
Lee, Hang [3 ]
Kato, Koji [1 ]
Yonetsu, Taishi [1 ]
Jang, Ik-Kyung [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA 02115 USA
[2] Kyung Hee Univ, Div Cardiol, Coll Med, Seoul, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Biostat, Boston, MA USA
关键词
Time domain; Frequency domain; Optical coherence tomography; Intravascular ultrasound; CORONARY-ARTERIES; ANGIOGRAPHY; VALIDATION; CATHETER; DISEASE; SYSTEM;
D O I
10.1007/s10554-012-0179-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lumen dimensions measured by time-domain optical coherence tomography (TD-OCT) may be influenced by the hemodynamic effect of proximal balloon occlusion. Frequency-domain OCT (FD-OCT) does not require the interruption of blood flow. Therefore, we compared the coronary lumen dimensions measured by TD-OCT, FD-OCT, and intravascular ultrasound (IVUS) in both stented and non-stented segments. Twenty patients who underwent both IVUS and OCT imaging (10 for TD- and 10 for FD-OCT) after stent implantation were included. The maximum, minimum, and mean diameters and areas were measured at the proximal and distal stent edges, as well as 3 mm inside and 5 mm outside of both edges. The measurements inside stent showed no significant differences between IVUS and TD- or FD-OCT. The lumen mean diameters and areas measured by IVUS at 5 mm outside stent were similar to those measured by FD-OCT (Distal; 3.07 +/- A 0.7 vs 3.03 +/- A 0.7 mm, p = 0.08 and 7.80 +/- A 4.0 vs 7.72 +/- A 4.1 mm(2), p = 0.07, respectively. Proximal; 3.25 +/- A 0.7 vs 3.23 +/- A 0.7 mm, p = 0.09 and 8.78 +/- A 3.8 vs 8.65 +/- A 3.7 mm(2), p = 0.08, respectively), but were greater than those measured by TD-OCT (Distal; 2.75 +/- A 0.5 vs 2.29 +/- A 0.5 mm, p = 0.0001 and 6.15 +/- A 2.6 vs 4.38 +/- A 1.9 mm(2), p = 0.0002, respectively. Proximal; 3.27 +/- A 0.6 vs 2.69 +/- A 0.6 mm, p = 0.0001 and 8.64 +/- A 3.4 vs 6.12 +/- A 2.7 mm(2), p = 0.0001 respectively). The interaction between TD- and FD-OCT for lumen dimension measurements at 5 mm outside stent was statistically significant. Vessel dimension measurements were similar between IVUS and FD-OCT in native vessel unlike with TD-OCT. Therefore, we might adapt the IVUS criteria of lesion severity for percutaneous coronary intervention to FD-OCT.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 22 条
[1]   Current and future developments in intracoronary optical coherence tomography imaging [J].
Barlis, Peter ;
Schmitt, Joseph M. .
EUROINTERVENTION, 2009, 4 (04) :529-533
[2]  
Chae J S, 1992, J Am Soc Echocardiogr, V5, P577
[3]   High resolution in vivo intra-arterial imaging with optical coherence tomography [J].
Fujimoto, JG ;
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Pitris, C ;
Brezinski, ME .
HEART, 1999, 82 (02) :128-133
[4]  
GE JB, 1994, BRIT HEART J, V71, P572
[5]   Quantitative Ex Vivo and In Vivo Comparison of Lumen Dimensions Measured by Optical Coherence Tomography and Intravascular Ultrasound in Human Coronary Arteries [J].
Gonzalo, Nieves ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
van Soest, Gijs ;
Okamura, Takayuki ;
Ligthart, Jurgen ;
Knaapen, Michiel ;
Verheye, Stefan ;
Bruining, Nico ;
Regar, Evelyn .
REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (06) :615-624
[6]   Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stenting [J].
Guagliumi, Giulio ;
Sirbu, Vasile .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :237-247
[7]  
Gutierrez-Chico JL, 2011, INT J CARDIOVASC IMA
[8]   Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound [J].
Jang, IK ;
Bouma, BE ;
Kang, DH ;
Park, SJ ;
Park, SW ;
Seung, KB ;
Choi, KB ;
Shishkov, M ;
Schlendorf, K ;
Pomerantsev, E ;
Houser, SL ;
Aretz, HT ;
Tearney, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) :604-609
[9]   In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter:: A comparison with intravascular ultrasound [J].
Kawase, Y ;
Hoshino, K ;
Yoneyama, R ;
McGregor, J ;
Hajjar, RJ ;
Jang, IK ;
Hayase, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (10) :1343-1349
[10]   Assessment of coronary intima-media thickness by optical coherence tomography - Comparison with intravascular ultrasound [J].
Kume, T ;
Akasaka, T ;
Kawamoto, T ;
Watanabe, N ;
Toyota, E ;
Neishi, Y ;
Sukmawan, R ;
Sadahira, Y ;
Yoshida, K .
CIRCULATION JOURNAL, 2005, 69 (08) :903-907