摘要
The ability to replace or augment diseased body parts totally or partially has improved both the quality and life span of human population. The decline in surgical risks during recent decades has encouraged the development of more complex procedures for prosthetic implantation. Additionally, a variety of extracorporeal devices. such as the heart, lung and blood dialysis machines are used routinely, but these prosthetic elements have several limitations. Hence, research projects are currently underway to overcome the limitations of synthetic materials by developing formulations with varying properties, such as asymptomatic. long-term function in the human physiological environment, etc., to meet the needs of biomedical surgeons. This review focuses on the several biomaterials corrosion and its measures to prevent corrosion.
引用
收藏
页码:855 / 869
页数:15
相关论文
共 107 条
[31]   De-alloying of type 316 stainless steel in hot, concentrated sodium hydroxide solution [J].
Deakin, J ;
Dong, ZH ;
Lynch, B ;
Newman, RC .
CORROSION SCIENCE, 2004, 46 (09) :2117-2133
[32]   PLASMA SPRAYED COATINGS OF HYDROXYLAPATITE [J].
DEGROOT, K ;
GEESINK, R ;
KLEIN, CPAT ;
SEREKIAN, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (12) :1375-1381
[33]   METAL-ION RELEASE AFTER TOTAL HIP-REPLACEMENT [J].
DOBBS, HS ;
MINSKI, MJ .
BIOMATERIALS, 1980, 1 (04) :193-198
[34]  
DOELKER E, 1993, BIOPOLYMERS, P200
[35]  
DORR LD, 1990, CLIN ORTHOP RELAT R, V261, P82
[36]   In vitro corrosion behavior of bioceramic, metallic, and bioceramic-metallic coated stainless steel dental implants [J].
Fathi, MH ;
Salehi, M ;
Saatchi, A ;
Mortazavi, V ;
Moosavi, SB .
DENTAL MATERIALS, 2003, 19 (03) :188-198
[37]  
Fontana M. G., 1967, CORROSION ENG
[38]  
FREEMAN BA, 1982, LAB INVEST, V47, P412
[39]  
GIBSON N, 2002, USE ALLOYS PROSTHESI, P48
[40]   IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544