Determination of nicousamide in human plasma by liquid chromatography-tandem mass spectrometry

被引:0
作者
Qi, Wenyuan [1 ,2 ]
Zhao, Qian [1 ,2 ]
Liu, Hongzhong [1 ,2 ]
Jiang, Ji [1 ,2 ]
Chen, Xiaoguang [3 ,4 ]
Hu, Pei [1 ,2 ]
机构
[1] Beijing Union Med Coll Hosp, Clin Pharmacol Res Ctr, Beijing 100032, Peoples R China
[2] Chinese Acad Med Sci, Beijing 100032, Peoples R China
[3] Chinese Acad Med Sci, Inst Mat Med, Beijing 100050, Peoples R China
[4] Perking Union Med Coll, Beijing 100050, Peoples R China
关键词
Nicousamide; LC-MS/MS; Human Plasma; Pharmacokinetics; Diabetic nephropathy; GLYCATION END-PRODUCTS; DIABETIC-NEPHROPATHY;
D O I
10.1016/j.jpba.2013.01.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific ultra-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for the determination of nicousamide in human plasma. This method has also been validated in terms of selectivity, linearity, lower limit of quantification (LLOQ), accuracy, precision, stability, matrix effect and recovery. Chromatography was carried out on an Acquity UPLC CSH C18 column and mass spectrometric analysis was performed using an QTrap5500 mass spectrometer coupled with electro-spray ionization (ESI) source in the Negative ion mode. The MRM transition of m/z 399 -> 353 was used to quantify nicousamide. The assay was validated from 1 to 1000 ng/mL for nicousamide. Intra- and Inter-day precision for nicousamide was <13.1%, method accuracy (RE%) was between -7.5 and 8.8%. This method was used to support a clinical study where a single oral dose was administered by Chinese healthy volunteers to investigate the pharmacokinetics of nicousamide. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 9 条
[1]   Advanced glycation endproducts: what is their relevance to diabetic complications? [J].
Ahmed, N. ;
Thornalley, P. J. .
DIABETES OBESITY & METABOLISM, 2007, 9 (03) :233-245
[2]  
[Anonymous], 2001, GUID IND BIOAN METH
[3]  
[Anonymous], 2012, IDF DIAB ATL
[4]   Prevention of loss of renal function over time in patients with diabetic nephropathy [J].
Barnett, A .
AMERICAN JOURNAL OF MEDICINE, 2006, 119 (05) :40S-47S
[5]   US Renal Data System 2011 Annual Data Report [J].
Collins, Allan J. ;
Foley, Robert N. ;
Chavers, Blanche ;
Gilbertson, David ;
Herzog, Charles ;
Johansen, Kirsten ;
Kasiske, Bertram ;
Kutner, Nancy ;
Liu, Jiannong ;
St Peter, Wendy ;
Guo, Haifeng ;
Gustafson, Sally ;
Heubner, Brooke ;
Lamb, Kenneth ;
Li, Shuling ;
Li, Suying ;
Peng, Yi ;
Qiu, Yang ;
Roberts, Tricia ;
Skeans, Melissa ;
Snyder, Jon ;
Solid, Craig ;
Thompson, Bryn ;
Wang, Changchun ;
Weinhandl, Eric ;
Zaun, David ;
Arko, Cheryl ;
Chen, Shu-Cheng ;
Daniels, Frank ;
Ebben, James ;
Frazier, Eric ;
Hanzlik, Christopher ;
Johnson, Roger ;
Sheets, Daniel ;
Wang, Xinyue ;
Forrest, Beth ;
Constantini, Edward ;
Everson, Susan ;
Eggers, Paul ;
Agodoa, Lawrence .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2012, 59 (01) :EVII-E418
[6]   Diabetic nephropathy: Where hemodynamics meets metabolism [J].
Forbes, J. M. ;
Fukami, K. ;
Cooper, M. E. .
EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2007, 115 (02) :69-84
[7]   Nicousamide blocks the effects of advanced glycation end products on renal cells [J].
Li, Hongyan ;
Zhang, Yi ;
Wang, Hongbo ;
Zheng, Xuguang ;
Chen, Xiaoguang .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2012, 674 (2-3) :455-459
[8]   XLF-III-43, a novel coumarin-aspirin compound, prevents diabetic nephropathy in rats via inhibiting advanced glycation end products [J].
Li, Hongyan ;
Zheng, Xuguang ;
Wang, Hongbo ;
Zhang, Yi ;
Xin, Hongqi ;
Chen, Xiaoguang .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2010, 627 (1-3) :340-347
[9]   A HPLC method for determination of nicousamide in dog plasma and its application to pharmacokinetic studies [J].
Sheng, Li ;
Chen, Hui ;
Li, Yan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2) :99-103