Comparison of single breath hyperpolarized129Xe MRI with dynamic19F MRI in cystic fibrosis lung disease

被引:17
作者
McCallister, Andrew [1 ,2 ]
Chung, Sang Hun [3 ]
Antonacci, Michael [1 ,2 ]
Powell, Margret Z. [4 ]
Ceppe, Agathe S. [4 ]
Donaldson, Scott H. [4 ,5 ]
Lee, Yueh Z. [1 ,2 ,3 ,4 ,6 ]
Branca, Rosa Tamara [1 ,2 ]
Goralski, Jennifer L. [4 ,5 ,7 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Marsico Lung Inst, UNC Cyst Fibrosis Ctr, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Div Pulm & Crit Care Med, Chapel Hill, NC 27599 USA
[6] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[7] Univ N Carolina, Div Pediat Pulmonol, Chapel Hill, NC 27599 USA
关键词
cystic fibrosis; hyperpolarized gas; perflorinated gas imaging; VDP; ventilation defect; HEALTHY-VOLUNTEERS; XE-129; GAS; TOLERABILITY; VENTILATION; HE-3;
D O I
10.1002/mrm.28457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To quantitatively compare dynamic(19)F and single breath hyperpolarized(129)Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic(19)F and single breath(129)Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between(19)F early-breath,F-19 maximum-ventilation,Xe-129 low-resolution, and(129)Xe high-resolution images were compared. Dynamic(19)F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between(129)Xe and(19)F. Results VDP values from high-resolution(129)Xe images were greater than from low-resolution images (P= .001), although these values were significantly correlated (r = 0.68,P= .03). Early-breath(19)F VDP and max-vent(19)F VDP also showed significant correlation (r = 0.75,P= .012), with early-breath(19)F VDP values being significantly greater (P< .001). No correlation in VDP values were detected between either(19)F method or high-res(129)Xe images. In addition, the location and volume of ventilation defects were often different when comparing(129)Xe and(19)F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. Conclusion In CF subjects, ventilation abnormalities are identified by both(19)F and (HPXe)-Xe-129 imaging. However, these ventilation abnormalities are not entirely congruent.F-19 and (HPXe)-Xe-129 imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.
引用
收藏
页码:1028 / 1038
页数:11
相关论文
共 50 条
[21]   Free-breathing 3D phase-resolved functional lung MRI vs breath-hold hyperpolarized 129Xe ventilation MRI in patients with chronic obstructive pulmonary disease and healthy volunteers [J].
Klimes, Filip ;
Kern, Agilo Luitger ;
Voskrebenzev, Andreas ;
Gutberlet, Marcel ;
Grimm, Robert ;
Mueller, Robin Aaron ;
Behrendt, Lea ;
Kaireit, Till Frederik ;
Glandorf, Julian ;
Alsady, Tawfik Moher ;
Wacker, Frank ;
Hohlfeld, Jens M. ;
Vogel-Claussen, Jens .
EUROPEAN RADIOLOGY, 2024, :943-956
[22]   Hyperpolarized 129Xe lung MRI in spontaneously breathing mice with respiratory gated fast imaging and its application to pulmonary functional imaging [J].
Imai, Hirohiko ;
Kimura, Atsuomi ;
Hori, Yuki ;
Iguchi, Satoshi ;
Kitao, Takuya ;
Okubo, Emi ;
Ito, Tsuyoshi ;
Matsuzaki, Toshio ;
Fujiwara, Hideaki .
NMR IN BIOMEDICINE, 2011, 24 (10) :1343-1352
[23]   Diffusion-Weighted Hyperpolarized 129Xe MRI in Healthy Volunteers and Subjects With Chronic Obstructive Pulmonary Disease [J].
Kaushik, S. Sivaram ;
Cleveland, Zackary I. ;
Cofer, Gary P. ;
Metz, Gregory ;
Beaver, Denise ;
Nouls, John ;
Kraft, Monica ;
Auffermann, William ;
Wolber, Jan ;
McAdams, H. Page ;
Driehuys, Bastiaan .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :1155-1165
[24]   Three-Dimensional Free-Breathing Ultrashort Echo Time (UTE) 1H MRI Regional Ventilation: Comparison With Hyperpolarized 129Xe MRI and Pulmonary Function Testing in Healthy Volunteers and People With Cystic Fibrosis [J].
Tan, Fei ;
Eddy, Rachel L. ;
Diamond, Vanessa M. ;
Rayment, Jonathan H. ;
Larson, Peder E. Z. .
NMR IN BIOMEDICINE, 2025, 38 (06)
[25]   The assessment of short- and long-term changes in lung function in cystic fibrosis using 129Xe MRI [J].
Smith, Laurie J. ;
Horsley, Alex ;
Bray, Jody ;
Hughes, Paul J. C. ;
Biancardi, Alberto ;
Norquay, Graham ;
Wildman, Martin ;
West, Noreen ;
Marshall, Helen ;
Wild, Jim M. .
EUROPEAN RESPIRATORY JOURNAL, 2020, 56 (06)
[26]   Comparison of Functional Free-Breathing Pulmonary 1H and Hyperpolarized 129Xe Magnetic Resonance Imaging in Pediatric Cystic Fibrosis [J].
Couch, Marcus J. ;
Munidasa, Samal ;
Rayment, Jonathan H. ;
Voskrebenzev, Andreas ;
Seethamraju, Ravi Teja ;
Vogel-Claussen, Jens ;
Ratjen, Felix ;
Santyr, Giles .
ACADEMIC RADIOLOGY, 2021, 28 (08) :E209-E218
[27]   Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral [J].
Bdaiwi, Abdullah S. ;
Willmering, Matthew M. ;
Wang, Hui ;
Cleveland, Zackary, I .
MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) :1342-1356
[28]   Correlation of Lung Clearance Index with Hyperpolarized 129Xe Magnetic Resonance Imaging in Pediatric Subjects with Cystic Fibrosis [J].
Kanhere, Nikhil ;
Couch, Marcus J. ;
Kowalik, Krzysztof ;
Zanette, Brandon ;
Rayment, Jonathan H. ;
Manson, David ;
Subbarao, Padma ;
Ratjen, Felix ;
Santyr, Giles .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 196 (08) :1073-1075
[29]   Comparison of 3He and 129Xe MRI for Evaluation of Lung Microstructure and Ventilation at 1.5T [J].
Stewart, Neil J. ;
Chan, Ho-Fung ;
Hughes, Paul J. C. ;
Horn, Felix C. ;
Norquay, Graham ;
Rao, Madhwesha ;
Yates, Denise P. ;
Ireland, Rob H. ;
Hatton, Matthew Q. ;
Tahir, Bilal A. ;
Ford, Paul ;
Swift, Andrew J. ;
Lawson, Rod ;
Marshall, Helen ;
Collier, Guilhem J. ;
Wild, Jim M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (03) :632-642
[30]   A Comparison of Two Hyperpolarized 129Xe MRI Ventilation Quantification Pipelines: The Effect of Signal to Noise Ratio [J].
He, Mu ;
Zha, Wei ;
Tan, Fei ;
Rankine, Leith ;
Fain, Sean ;
Driehuys, Bastiaan .
ACADEMIC RADIOLOGY, 2019, 26 (07) :949-959