Comparison of single breath hyperpolarized129Xe MRI with dynamic19F MRI in cystic fibrosis lung disease

被引:15
|
作者
McCallister, Andrew [1 ,2 ]
Chung, Sang Hun [3 ]
Antonacci, Michael [1 ,2 ]
Powell, Margret Z. [4 ]
Ceppe, Agathe S. [4 ]
Donaldson, Scott H. [4 ,5 ]
Lee, Yueh Z. [1 ,2 ,3 ,4 ,6 ]
Branca, Rosa Tamara [1 ,2 ]
Goralski, Jennifer L. [4 ,5 ,7 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Marsico Lung Inst, UNC Cyst Fibrosis Ctr, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Div Pulm & Crit Care Med, Chapel Hill, NC 27599 USA
[6] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[7] Univ N Carolina, Div Pediat Pulmonol, Chapel Hill, NC 27599 USA
关键词
cystic fibrosis; hyperpolarized gas; perflorinated gas imaging; VDP; ventilation defect; HEALTHY-VOLUNTEERS; XE-129; GAS; TOLERABILITY; VENTILATION; HE-3;
D O I
10.1002/mrm.28457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To quantitatively compare dynamic(19)F and single breath hyperpolarized(129)Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic(19)F and single breath(129)Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between(19)F early-breath,F-19 maximum-ventilation,Xe-129 low-resolution, and(129)Xe high-resolution images were compared. Dynamic(19)F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between(129)Xe and(19)F. Results VDP values from high-resolution(129)Xe images were greater than from low-resolution images (P= .001), although these values were significantly correlated (r = 0.68,P= .03). Early-breath(19)F VDP and max-vent(19)F VDP also showed significant correlation (r = 0.75,P= .012), with early-breath(19)F VDP values being significantly greater (P< .001). No correlation in VDP values were detected between either(19)F method or high-res(129)Xe images. In addition, the location and volume of ventilation defects were often different when comparing(129)Xe and(19)F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. Conclusion In CF subjects, ventilation abnormalities are identified by both(19)F and (HPXe)-Xe-129 imaging. However, these ventilation abnormalities are not entirely congruent.F-19 and (HPXe)-Xe-129 imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.
引用
收藏
页码:1028 / 1038
页数:11
相关论文
共 50 条
  • [11] Hyperpolarized 129 Xe MRI, 99m Tc scintigraphy, and SPECT in lung ventilation imaging: a quantitative comparison
    Peiffer, J. D.
    Altes, Talissa
    Ruset, Iulian C.
    Hersman, F. W.
    Mugler, John P.
    Meyer, Craig H.
    Mata, Jamie
    Qing, Kun
    Thomen, Robert
    ACADEMIC RADIOLOGY, 2024, 31 (04) : 1666 - 1675
  • [12] Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients
    Shammi, Ummul Afia
    D'Alessandro, Michelle Felicia
    Altes, Talissa
    Hersman, F. William
    Ruset, Iulian C.
    Mugler, John, III
    Meyer, Craig
    Mata, Jamie
    Qing, Kun
    Thomen, Robert
    ACADEMIC RADIOLOGY, 2022, 29 : S82 - S90
  • [13] Highly and Adaptively Undersampling Pattern for Pulmonary Hyperpolarized 129Xe Dynamic MRI
    Xiao, Sa
    Deng, He
    Duan, Caohui
    Xie, Junshuai
    Li, Haidong
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (05) : 1240 - 1250
  • [14] Comparison of ventilation defects quantified by Technegas SPECT and hyperpolarized 129Xe MRI
    Radadia, Nisarg
    Friedlander, Yonni
    Priel, Eldar
    Konyer, Norman B.
    Huang, Chynna
    Jamal, Mobin
    Farncombe, Troy
    Marriott, Christopher
    Finley, Christian
    Agzarian, John
    Dolovich, Myrna
    Noseworthy, Michael D.
    Nair, Parameswaran
    Shargall, Yaron
    Svenningsen, Sarah
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [15] Intra- and Inter-visit Repeatability of 129Xenon Multiple-Breath Washout MRI in Children With Stable Cystic Fibrosis Lung Disease
    Alam, Faiyza S.
    Zanette, Brandon
    Munidasa, Samal
    Braganza, Sharon
    Li, Daniel
    Woods, Jason C.
    Ratjen, Felix
    Santyr, Giles
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (03) : 936 - 948
  • [16] 3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosis
    Cleveland, Zackary I.
    Virgincar, Rohan S.
    Qi, Yi
    Robertson, Scott H.
    Degan, Simone
    Driehuys, Bastiaan
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1502 - 1514
  • [17] A 3D stack-of-spirals approach for rapid hyperpolarized 129Xe ventilation mapping in pediatric cystic fibrosis lung disease
    Zanette, Brandon
    Munidasa, Samal
    Friedlander, Yonni
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (03) : 1083 - 1091
  • [18] 1H and 129Xe MRI to detect functional and structural lung disease in sub-clinical cystic fibrosis
    Smith, Laurie
    Hughes, David
    Chan, Ho-Fung
    Johnson, Kevin
    Bray, Jody
    Rodgers, Oliver
    Collier, Guilhem
    Norquay, Graham
    Biancardi, Alberto
    Hughes, Paul
    Kotecha, Sailesh
    Wildman, Martin
    West, Noreen
    Horsley, Alex
    Vogel-Claussen, Jens
    Tiddens, Harm
    Marshall, Helen
    Wild, Jim
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [19] 3D Single-Breath Chemical Shift Imaging Hyperpolarized Xe-129 MRI of Healthy, CF, IPF, and COPD Subjects
    Guan, Steven
    Tustison, Nick
    Qing, Kun
    Shim, Yun Michael
    Mugler, John, III
    Altes, Talissa
    Albon, Dana
    Froh, Deborah
    Mehrad, Borna
    Patrie, James
    Ropp, Alan
    Miller, Braden
    Nehrbas, Jill
    Mata, Jaime
    TOMOGRAPHY, 2022, 8 (05) : 2574 - 2587
  • [20] Volumetric dynamic oxygen-enhanced MRI (OE-MRI): comparison with CT Brody score and lung function in cystic fibrosis patients
    Martini, K.
    Gygax, C. M.
    Benden, C.
    Morgan, A. R.
    Parker, G. J. M.
    Frauenfelder, T.
    EUROPEAN RADIOLOGY, 2018, 28 (10) : 4037 - 4047