Comparison of single breath hyperpolarized129Xe MRI with dynamic19F MRI in cystic fibrosis lung disease

被引:18
作者
McCallister, Andrew [1 ,2 ]
Chung, Sang Hun [3 ]
Antonacci, Michael [1 ,2 ]
Powell, Margret Z. [4 ]
Ceppe, Agathe S. [4 ]
Donaldson, Scott H. [4 ,5 ]
Lee, Yueh Z. [1 ,2 ,3 ,4 ,6 ]
Branca, Rosa Tamara [1 ,2 ]
Goralski, Jennifer L. [4 ,5 ,7 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Marsico Lung Inst, UNC Cyst Fibrosis Ctr, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Div Pulm & Crit Care Med, Chapel Hill, NC 27599 USA
[6] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[7] Univ N Carolina, Div Pediat Pulmonol, Chapel Hill, NC 27599 USA
关键词
cystic fibrosis; hyperpolarized gas; perflorinated gas imaging; VDP; ventilation defect; HEALTHY-VOLUNTEERS; XE-129; GAS; TOLERABILITY; VENTILATION; HE-3;
D O I
10.1002/mrm.28457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To quantitatively compare dynamic(19)F and single breath hyperpolarized(129)Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic(19)F and single breath(129)Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between(19)F early-breath,F-19 maximum-ventilation,Xe-129 low-resolution, and(129)Xe high-resolution images were compared. Dynamic(19)F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between(129)Xe and(19)F. Results VDP values from high-resolution(129)Xe images were greater than from low-resolution images (P= .001), although these values were significantly correlated (r = 0.68,P= .03). Early-breath(19)F VDP and max-vent(19)F VDP also showed significant correlation (r = 0.75,P= .012), with early-breath(19)F VDP values being significantly greater (P< .001). No correlation in VDP values were detected between either(19)F method or high-res(129)Xe images. In addition, the location and volume of ventilation defects were often different when comparing(129)Xe and(19)F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. Conclusion In CF subjects, ventilation abnormalities are identified by both(19)F and (HPXe)-Xe-129 imaging. However, these ventilation abnormalities are not entirely congruent.F-19 and (HPXe)-Xe-129 imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.
引用
收藏
页码:1028 / 1038
页数:11
相关论文
共 32 条
[21]   Standardisation of spirometry [J].
Miller, MR ;
Hankinson, J ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Crapo, R ;
Enright, P ;
van der Grinten, CPM ;
Gustafsson, P ;
Jensen, R ;
Johnson, DC ;
MacIntyre, N ;
McKay, R ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Viegi, G ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :319-338
[22]   Optimized and accelerated 19F-MRI of inhaled perfluoropropane to assess regional pulmonary ventilation [J].
Neal, Mary A. ;
Pippard, Benjamin J. ;
Hollingsworth, Kieren G. ;
Maunder, Adam ;
Dutta, Prosenjit ;
Simpson, A. John ;
Blamire, Andrew M. ;
Wild, James M. ;
Thelwall, Peter E. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) :1301-1311
[23]   1H-guided reconstruction of 19F gas MRI in COPD patients [J].
Obert, Arnd Jonathan ;
Gutberlet, Marcel ;
Kern, Agilo Luitger ;
Kaireit, Till Frederik ;
Grimm, Robert ;
Wacker, Frank ;
Vogel-Claussen, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) :1336-1346
[24]   Lung Morphometry Using Hyperpolarized 129Xe Apparent Diffusion Coefficient Anisotropy in Chronic Obstructive Pulmonary Disease [J].
Ouriadov, Alexei ;
Farag, Adam ;
Kirby, Miranda ;
McCormack, David G. ;
Parraga, Grace ;
Santyr, Giles E. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) :1699-1706
[25]   High Resolution Spectroscopy and Chemical Shift Imaging of Hyperpolarized 129Xe Dissolved in the Human Brain In Vivo at 1.5 Tesla [J].
Rao, Madhwesha ;
Stewart, Neil J. ;
Norquay, Graham ;
Griffiths, Paul D. ;
Wild, Jim M. .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) :2227-2234
[26]   Hyperpolarized Gas MR Imaging Technique and Applications [J].
Roos, Justus E. ;
McAdams, Holman P. ;
Kaushik, S. Sivaram ;
Driehuys, Bastiaan .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (02) :217-+
[27]   Hyperpolarized 129Xe Magnetic Resonance Imaging: Tolerability in Healthy Volunteers and Subjects with Pulmonary Disease [J].
Shukla, Yajur ;
Wheatley, Andrew ;
Kirby, Miranda ;
Svenningsen, Sarah ;
Farag, Adam ;
Santyr, Giles E. ;
Paterson, Nigel A. M. ;
McCormack, David G. ;
Parraga, Grace .
ACADEMIC RADIOLOGY, 2012, 19 (08) :941-951
[28]   Hyperpolarized 129Xe for investigation of mild cystic fibrosis lung disease in pediatric patients [J].
Thomen, Robert P. ;
Walkup, Laura L. ;
Roach, David J. ;
Cleveland, Zackary I. ;
Clancy, John P. ;
Woods, Jason C. .
JOURNAL OF CYSTIC FIBROSIS, 2017, 16 (02) :275-282
[29]   Feasibility, tolerability and safety of pediatric hyperpolarized 129Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis [J].
Walkup, Laura L. ;
Thomen, Robert P. ;
Akinyi, Teckla G. ;
Watters, Erin ;
Ruppert, Kai ;
Clancy, John P. ;
Woods, Jason C. ;
Cleveland, Zackary I. .
PEDIATRIC RADIOLOGY, 2016, 46 (12) :1651-1662
[30]   Simultaneous Imaging of Lung Structure and Function with Triple-Nuclear Hybrid MR Imaging [J].
Wild, Jim M. ;
Marshall, Helen ;
Xu, Xiaoxun ;
Norquay, Graham ;
Parnell, Steven R. ;
Clemence, Matthew ;
Griffiths, Paul D. ;
Parra-Robles, Juan .
RADIOLOGY, 2013, 267 (01) :251-255