Comparison of single breath hyperpolarized129Xe MRI with dynamic19F MRI in cystic fibrosis lung disease

被引:15
|
作者
McCallister, Andrew [1 ,2 ]
Chung, Sang Hun [3 ]
Antonacci, Michael [1 ,2 ]
Powell, Margret Z. [4 ]
Ceppe, Agathe S. [4 ]
Donaldson, Scott H. [4 ,5 ]
Lee, Yueh Z. [1 ,2 ,3 ,4 ,6 ]
Branca, Rosa Tamara [1 ,2 ]
Goralski, Jennifer L. [4 ,5 ,7 ]
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Marsico Lung Inst, UNC Cyst Fibrosis Ctr, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Div Pulm & Crit Care Med, Chapel Hill, NC 27599 USA
[6] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[7] Univ N Carolina, Div Pediat Pulmonol, Chapel Hill, NC 27599 USA
关键词
cystic fibrosis; hyperpolarized gas; perflorinated gas imaging; VDP; ventilation defect; HEALTHY-VOLUNTEERS; XE-129; GAS; TOLERABILITY; VENTILATION; HE-3;
D O I
10.1002/mrm.28457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To quantitatively compare dynamic(19)F and single breath hyperpolarized(129)Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease. Methods Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic(19)F and single breath(129)Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between(19)F early-breath,F-19 maximum-ventilation,Xe-129 low-resolution, and(129)Xe high-resolution images were compared. Dynamic(19)F images were used to determine gas wash-in/out rates in regions of ventilation congruency and mismatch between(129)Xe and(19)F. Results VDP values from high-resolution(129)Xe images were greater than from low-resolution images (P= .001), although these values were significantly correlated (r = 0.68,P= .03). Early-breath(19)F VDP and max-vent(19)F VDP also showed significant correlation (r = 0.75,P= .012), with early-breath(19)F VDP values being significantly greater (P< .001). No correlation in VDP values were detected between either(19)F method or high-res(129)Xe images. In addition, the location and volume of ventilation defects were often different when comparing(129)Xe and(19)F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash-in and wash-out. Conclusion In CF subjects, ventilation abnormalities are identified by both(19)F and (HPXe)-Xe-129 imaging. However, these ventilation abnormalities are not entirely congruent.F-19 and (HPXe)-Xe-129 imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non-ventilated regions in the lungs.
引用
收藏
页码:1028 / 1038
页数:11
相关论文
共 50 条
  • [1] Assessing the feasibility of hyperpolarized 129Xe multiple-breath washout MRI in pediatric cystic fibrosis
    Couch, Marcus J.
    Morgado, Felipe
    Kanhere, Nikhil
    Kowalik, Krzysztof
    Rayment, Jonathan H.
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 304 - 311
  • [2] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 775 - 787
  • [3] Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis
    Munidasa, Samal
    Zanette, Brandon
    Dumas, Marie-Pier
    Wee, Wallace
    Braganza, Sharon
    Li, Daniel
    Ratjen, Felix
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2024,
  • [4] Quantifying abnormal alveolar microstructure in cystic fibrosis lung disease via hyperpolarized 129Xe diffusion MRI
    Bdaiwi, Abdullah S.
    Svoboda, Alexandra M.
    Murdock, Kyle E.
    Hendricks, Alexandra
    Hossain, Md M.
    Kramer, Elizabeth L.
    Brewington, John J.
    Willmering, Matthew M.
    Woods, Jason C.
    Walkup, Laura L.
    Cleveland, Zackary I.
    JOURNAL OF CYSTIC FIBROSIS, 2024, 23 (05) : 926 - 935
  • [5] Validating in vivo hyperpolarized129Xe diffusion MRI and diffusion morphometry in the mouse lung
    Niedbalski, Peter J.
    Cochran, Alexander S.
    Freeman, Matthew S.
    Guo, Jinbang
    Fugate, Elizabeth M.
    Davis, Cory B.
    Dahlke, Jerry
    Quirk, James D.
    Varisco, Brian M.
    Woods, Jason C.
    Cleveland, Zackary I.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 2160 - 2173
  • [6] Hyperpolarized 129Xe for investigation of mild cystic fibrosis lung disease in pediatric patients
    Thomen, Robert P.
    Walkup, Laura L.
    Roach, David J.
    Cleveland, Zackary I.
    Clancy, John P.
    Woods, Jason C.
    JOURNAL OF CYSTIC FIBROSIS, 2017, 16 (02) : 275 - 282
  • [7] Hyperpolarized 129Xe MRI of the human lung
    Mugler, John P.
    Altes, Talissa A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) : 313 - 331
  • [8] Hyperpolarized 129Xe Lung MRI and Spectroscopy in Mechanically Ventilated Mice
    Costa, Mariah L.
    Plummer, Joseph W.
    Bdaiwi, Abdullah S.
    Albert, Brice J.
    Fugate, Elizabeth M.
    Niedbalski, Peter J.
    Lindquist, Diana M.
    Cleveland, Zackary I.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (212):
  • [9] A two-center analysis of hyperpolarized 129Xe lung MRI in stable pediatric cystic fibrosis: Potential as a biomarker for multi-site trials
    Couch, Marcus J.
    Thomen, Robert
    Kanhere, Nikhil
    Hu, Raymond
    Ratjen, Felix
    Woods, Jason
    Santyr, Giles
    JOURNAL OF CYSTIC FIBROSIS, 2019, 18 (05) : 728 - 733
  • [10] Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
    Doganay, Ozkan
    Matin, Tahreema N.
    Mcintyre, Anthony
    Burns, Brian
    Schulte, Rolf F.
    Gleeson, Fergus V.
    Bulte, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2597 - 2606