Monte Carlo calculation of the efficiency response of a low-background well-type HPGe detector

被引:34
作者
Laborie, JM [1 ]
Le Petit, G [1 ]
Abt, D [1 ]
Girard, M [1 ]
机构
[1] CEA, DAM, Dept Analyse & Surveillance Environm, F-91680 Bruyeres Le Chatel, France
关键词
well-type HPGe detectors; gamma-ray spectrometry; efficiency calibration; Monte Carlo simulation; true coincidence-summing;
D O I
10.1016/S0168-9002(01)00942-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Well-type HPGe detectors are well suited for the analysis of small amounts of environmental samples, as they can combine both low background and high detection efficiency. A low-background well-type detector is installed in the Modane underground Laboratory. In the well geometry, coincidence-summing effects are high and make construction of the full energy peak efficiency curve difficult with the usual calibration standard, especially in the: high energy range. Using the GEANT code, taking into account a detailed description of the detector and the source, efficiency curves have been modelled for several filling heights of the vial. With a special routine, taking into account the decay schemes of the radionuclides corrections have been computed for coincidence-summing effects that occur when measuring samples containing U-238, Th-232 or Cs-134. The results are found to be in good agreement with experimental data. It is shown that triple coincidences effect on counting losses accounts for 7-15% of pair coincidences effect in the case of the 604 and 796 keV lines of Cs-134. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:618 / 630
页数:13
相关论文
共 21 条
[1]  
BENABED A, 1996, ISN9612 U GREN 1 I S
[2]   Calibration of the well-type germanium gamma-ray detector employing two gamma-ray spectra [J].
Blaauw, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01) :146-153
[3]   MEASUREMENT OF LOW-LEVEL RADIOACTIVITY IN THE MODANE UNDERGROUND LABORATORY [J].
BOURLAT, Y ;
MILLIESLACROIX, JC ;
ABT, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :309-317
[4]  
BRONSON FL, 1996, WAST MAN 96 FEB 28 T
[5]  
BRUN R, GEANT3 DETECTOR DESC
[6]  
Debertin K., 1988, Gamma and X-Ray Spectrometry with Semiconductor Detectors, P258
[7]   COINCIDENCE-SUMMING CORRECTIONS FOR EXTENDED SOURCES IN GAMMA-RAY SPECTROMETRY USING MONTE-CARLO SIMULATION [J].
DECOMBAZ, M ;
GOSTELY, JJ ;
LAEDERMANN, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2) :152-159
[8]  
Gilmore G., 1995, Practical gamma-ray spectrometry
[9]  
*GROUP TRAV NORM, 1989, CEAR5506 GROUP TRAV
[10]   LOW-RADIOACTIVITY BACKGROUND TECHNIQUES [J].
HEUSSER, G .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1995, 45 :543-590