Robust and efficient location of T-wave ends in electrocardiogram

被引:0
作者
Zhang, Q [1 ]
Manriquez, AI [1 ]
Medigue, C [1 ]
Papelier, Y [1 ]
Sorine, M [1 ]
机构
[1] IRISA, INRIA, F-35042 Rennes, France
来源
Computers in Cardiology 2005, Vol 32 | 2005年 / 32卷
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new algorithm is proposed in this paper for T-wave end location in electrocardiogram (ECG). It mainly consists of the computation of an indicator related to the area covered by the T-wave curve and delimited in a special manner Based on simple assumptions, essentially on the concavity of the T-wave form, it is proved that the maximum of the computed indicator inside each cardiac cycle coincides with the T-wave end. The algorithm is robust to measurement noise, to wave form morphological variations and to baseline wander It is also computationally very simple: the main computation can be implemented as a simple finite impulse response (FIR) filter.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 50 条
[31]   T-WAVE ABNORMALITIES OF SPATIAL VELOCITY ELECTROCARDIOGRAM AND VENTRICULAR GRADIENT [J].
KAWANO, S ;
YAMAMOTO, M ;
SAWANOBORI, T ;
HIRAOKA, M ;
SAKAMOTO, Y .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1984, 48 (08) :871-871
[32]   Improved robust T-wave alternans detectors [J].
O. Meste ;
D. Janusek ;
S. Karczmarewicz ;
A. Przybylski ;
M. Kania ;
A. Maciag ;
R. Maniewski .
Medical & Biological Engineering & Computing, 2015, 53 :361-370
[33]   Improved robust T-wave alternans detectors [J].
Meste, O. ;
Janusek, D. ;
Karczmarewicz, S. ;
Przybylski, A. ;
Kania, M. ;
Maciag, A. ;
Maniewski, R. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (04) :361-370
[34]   A new hypothesis of the production of the T-wave in the electrocardiogram based on electrokinetic phenomena [J].
Miller, JR ;
Dent, RF .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1942, 28 :168-173
[35]   An enhanced T-wave delineation method using phasor transform in the electrocardiogram [J].
Rahul, J. ;
Sharma, L. D. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
[36]   A unified procedure for detecting, quantifying, and validating electrocardiogram T-wave alternans [J].
H. Naseri ;
H. Pourkhajeh ;
M. R. Homaeinezhad .
Medical & Biological Engineering & Computing, 2013, 51 :1031-1042
[37]   POST-VENTRICULAR TACHYCARDIA T-WAVE CHANGES IN AMBULATORY ELECTROCARDIOGRAM [J].
PINEIRO, DJ ;
BLANCO, MV ;
SUAREZ, LD .
MEDICINA-BUENOS AIRES, 1986, 46 (01) :43-47
[38]   HYPERVENTILATION-INDUCED T-WAVE CHANGES IN LIMB LEAD ELECTROCARDIOGRAM [J].
GOLDEN, GS ;
GOLDEN, LH ;
BEEREL, FR .
CHEST, 1975, 67 (01) :123-125
[39]   Isolated deep T-wave inversion on an electrocardiogram with normal wall motion [J].
Aoki, Yoshihiro ;
Kodera, Satoshi ;
Shakya, Sandeep ;
Ishiwaki, Hikaru ;
Ikeda, Masayuki ;
Kanda, Junji .
CLINICAL CASE REPORTS, 2015, 3 (07) :594-597
[40]   NORMAL RESPIRATORY VARIATION OF THE T-WAVE IN LEAD-I OF THE ELECTROCARDIOGRAM [J].
BLUMENTHAL, MJ ;
BLACKMAN, NS .
NEW YORK STATE JOURNAL OF MEDICINE, 1950, 50 (03) :335-337