Tracing Phosphate Ions Generated during Loop-Mediated Isothermal Amplification for Electrochemical Detection of Nosema bombycis Genomic DNA PTP1

被引:61
作者
Xie, Shunbi [1 ]
Yuan, Yali [1 ]
Chai, Yaqin [1 ]
Yuan, Ruo [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, State Key Lab Silkworm Genome Biol, Chongqing 400715, Peoples R China
基金
中国博士后科学基金;
关键词
QUANTITATIVE DETECTION; NUCLEIC-ACIDS; LAMP; POINT; CARE; MOLYBDOPHOSPHATE; NANOPARTICLES; IMMUNOSENSOR; REDUCTION; DIAGNOSIS;
D O I
10.1021/acs.analchem.5b01858
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, amplified DNA detection in a loop-mediated isothermal amplification (LAMP) was carried out in a complicated gel electrophoresis or with expensive fluorescence-based methods. Here, instead of direct detection that relies on amplified DNA, the indirect detection based on tracing phosphate ions (Pi) generated during LAMP by using an electrochemical method has been proposed for sensitive nucleic acid detection. Pyrophosphate (PPi) as the byproduct of nucleic acid polymerization reaction in LAMP was hydrolyzed into Pi by the preaddition of thermostable inorganic pyrophosphatase (PPase). Thus, the total amount of Pi in the LAMP-amplified sample was proportional to the amount of starting DNA templates. The obtained Pi could then react with acidic molybdate to form the molybdophosphate precipitates on the electrode surface, which serve as redox mediators to give a readily measurable electrochemical signal. The practicality of this strategy has been further demonstrated by employing it for sensitive and accurate quantification of Nosema bombycis genomic DNA PTP1. The electrochemical method allowed the quantitative analysis for target genomic DNA with a detection limit of 17 fg/mu L. Thus, we suppose that the novel method proposed in this work with superior sensitivity and specificity, as well as the simple feature, can be easily established for quantitative analysis of many other kinds of nucleic acids in the assistance of LAMP.
引用
收藏
页码:10268 / 10274
页数:7
相关论文
共 35 条
  • [1] Loop-mediated isothermal amplification (LAMP) for malarial parasites of humans: Would it come to clinical reality as a point-of-care test?
    Abdul-Ghani, Rashad
    Al-Mekhlafi, Abdulsalam M.
    Karanis, Panagiotis
    [J]. ACTA TROPICA, 2012, 122 (03) : 233 - 240
  • [2] Real-time electrochemical detection of pathogen DNA using electrostatic interaction of a redox probe
    Ahmed, Minhaz Uddin
    Nahar, Sharifun
    Safavieh, Mohammadali
    Zourob, Mohammed
    [J]. ANALYST, 2013, 138 (03) : 907 - 915
  • [3] Electrochemical genosensor for the rapid detection of GMO using loop-mediated isothermal amplification
    Ahmed, Minhaz Uddin
    Saito, Masato
    Hossain, M. Mosharraf
    Rao, S. Ramachandara
    Furui, Satoshi
    Hino, Akihiro
    Takamura, Yuzuru
    Takagi, Masahiro
    Tamiya, Eiichi
    [J]. ANALYST, 2009, 134 (05) : 966 - 972
  • [4] Hyd5 gene based analysis of cereals and malt for gushing-inducing Fusarium spp. by real-time LAMP using fluorescence and turbidity measurements
    Denschlag, Carla
    Vogel, Rudi F.
    Niessen, Ludwig
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2013, 162 (03) : 245 - 251
  • [5] Colorimetric method for detecting amplified nucleic acids
    Durward, E
    Harris, WJ
    [J]. BIOTECHNIQUES, 1998, 25 (04) : 608 - +
  • [6] Predicting Viruses Accurately by a Multiplex Microfluidic Loop-Mediated Isothermal Amplification Chip
    Fang, Xueen
    Chen, Hui
    Yu, Shaoning
    Jiang, Xingyu
    Kong, Jilie
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (03) : 690 - 695
  • [7] Loop-Mediated Isothermal Amplification Integrated on Microfluidic Chips for Point-of-Care Quantitative Detection of Pathogens
    Fang, Xueen
    Liu, Yingyi
    Kong, Jilie
    Jiang, Xingyu
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (07) : 3002 - 3006
  • [8] A new method of pebrine inspection of silkworm egg using multiprimer PCR
    Hatakeyama, Y
    Hayasaka, S
    [J]. JOURNAL OF INVERTEBRATE PATHOLOGY, 2003, 82 (03) : 148 - 151
  • [9] Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop-Mediated Isothermal Amplification
    Hsieh, Kuangwen
    Patterson, Adriana S.
    Ferguson, B. Scott
    Plaxco, Kevin W.
    Soh, H. Tom
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (20) : 4896 - 4900
  • [10] Development of Phage Immuno-Loop-Mediated Isothermal Amplification Assays for Organophosphorus Pesticides in Agro-products
    Hua, Xiude
    Yin, Wei
    Shi, Haiyan
    Li, Ming
    Wang, Yanru
    Wang, Hong
    Ye, Yonghao
    Kim, Hee Joo
    Gee, Shirley J.
    Wang, Minghua
    Liu, Fengquan
    Hammock, Bruce D.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (16) : 8441 - 8447