Transient and quasi-steady thermal behaviour of a building envelope due to retrofitted cavity wall and ceiling insulation

被引:43
作者
Byrne, Aimee [1 ]
Byrne, Gerard [2 ]
Davies, Anna [3 ]
Robinson, Anthony James [2 ]
机构
[1] Trinity Coll Dublin, Dept Civil Struct & Environm Engn, Dublin, Ireland
[2] Trinity Coll Dublin, Dept Mech & Mfg Engn, Dublin, Ireland
[3] Trinity Coll Dublin, Dept Geog, Dublin, Ireland
关键词
Retrofit; Energy efficiency; Insulation; Heat flux; Heat flow; Thermal resistance; In situ; HEAT-CAPACITY; TWIN RIVERS; RESISTANCE; SIMULATIONS; PERFORMANCE; BRICKS; MODEL;
D O I
10.1016/j.enbuild.2013.02.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate understanding of the thermal behaviour of building components is essential for predicting heating or cooling needs and facilitates the implementation of more successful energy saving strategies and retrofits. This paper focuses on a specific measure commonly introduced through the residential energy efficiency retrofit programmes in Ireland-insulation. Traditionally, assessments of the performance of building envelopes have been based on assumed thermal resistances of the materials involved, laboratory tests and computer modelling. The aim of the present work is to investigate the in situ thermal behaviour of a case study building and its components under transient and quasi-steady environmental conditions, comparing data before and after the fixing of cavity wall and ceiling insulation. The paper concludes by proposing that predicted values of heat loss using standardised assumed material properties of the existing structure do not reflect the actual values achieved in situ for this test case. These values greatly overestimated the impact of the retrofitted insulation on heat loss through the ceiling and wall. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:356 / 365
页数:10
相关论文
共 39 条
[11]   Properties of thermal insulation materials during extreme environment changes [J].
Bjork, Folke ;
Enochsson, Tomas .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (06) :2189-2195
[12]  
British Standards Institution, 1998, 19341998 BS EN
[13]  
CIBSE, 2007, GUID ENV DES
[14]  
Commission of the European Communities, 2008, COM2008772 COMM EUR
[15]  
Department of the Environment Heritage and Local Government, 2007, BUILD REG 2007 TECHN
[16]   Comparing different approaches to in situ measurement of building components thermal resistance [J].
Desogus, Giuseppe ;
Mura, Salvatore ;
Ricciu, Roberto .
ENERGY AND BUILDINGS, 2011, 43 (10) :2613-2620
[17]   Uncertainty in the thermal conductivity of insulation materials [J].
Dominguez-Munoz, Fernando ;
Anderson, Brian ;
Cejudo-Lopez, Jose M. ;
Carrillo-Andres, Antonio .
ENERGY AND BUILDINGS, 2010, 42 (11) :2159-2168
[18]  
Doran S., 2000, 78132 BUILD RES ESTA
[19]  
Eichhammer W., 1998, 1 MURE
[20]   U-value of a dried wall made of perforated porous clay bricks -: Hot box measurement versus numerical analysis [J].
Ghazi Wakili, K ;
Tanner, C .
ENERGY AND BUILDINGS, 2003, 35 (07) :675-680