Transient and quasi-steady thermal behaviour of a building envelope due to retrofitted cavity wall and ceiling insulation

被引:43
作者
Byrne, Aimee [1 ]
Byrne, Gerard [2 ]
Davies, Anna [3 ]
Robinson, Anthony James [2 ]
机构
[1] Trinity Coll Dublin, Dept Civil Struct & Environm Engn, Dublin, Ireland
[2] Trinity Coll Dublin, Dept Mech & Mfg Engn, Dublin, Ireland
[3] Trinity Coll Dublin, Dept Geog, Dublin, Ireland
关键词
Retrofit; Energy efficiency; Insulation; Heat flux; Heat flow; Thermal resistance; In situ; HEAT-CAPACITY; TWIN RIVERS; RESISTANCE; SIMULATIONS; PERFORMANCE; BRICKS; MODEL;
D O I
10.1016/j.enbuild.2013.02.044
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate understanding of the thermal behaviour of building components is essential for predicting heating or cooling needs and facilitates the implementation of more successful energy saving strategies and retrofits. This paper focuses on a specific measure commonly introduced through the residential energy efficiency retrofit programmes in Ireland-insulation. Traditionally, assessments of the performance of building envelopes have been based on assumed thermal resistances of the materials involved, laboratory tests and computer modelling. The aim of the present work is to investigate the in situ thermal behaviour of a case study building and its components under transient and quasi-steady environmental conditions, comparing data before and after the fixing of cavity wall and ceiling insulation. The paper concludes by proposing that predicted values of heat loss using standardised assumed material properties of the existing structure do not reflect the actual values achieved in situ for this test case. These values greatly overestimated the impact of the retrofitted insulation on heat loss through the ceiling and wall. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:356 / 365
页数:10
相关论文
共 39 条
[1]   Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential [J].
Al-Sanea, Sami A. ;
Zedan, M. F. ;
Al-Hussain, S. N. .
APPLIED ENERGY, 2012, 89 (01) :430-442
[2]   THE THERMAL-RESISTANCE OF AIRSPACES IN BUILDING CONSTRUCTIONS [J].
ANDERSON, BR .
BUILDING AND ENVIRONMENT, 1981, 16 (01) :35-39
[3]  
[Anonymous], 98691994 ISO
[4]  
[Anonymous], 2007, 69462007 ISO NSAI
[5]  
[Anonymous], 89901996 BS EN ISO
[6]  
[Anonymous], DON CLIM HIST
[7]   Thermal properties of a variable cavity wall [J].
Aviram, DP ;
Fried, AN ;
Roberts, JJ .
BUILDING AND ENVIRONMENT, 2001, 36 (09) :1057-1072
[8]  
Baker P., 2008, In situ U-value measurements in traditional buildings -preliminary results
[9]  
Baker P., 2008, 2 HIST SCOTL TECHN C
[10]  
Baker P, 2011, 10 HIST SCOTL CONS G