Stent-grafts for revision of TIPS stenoses and occlusions: A clinical pilot study

被引:64
作者
Saxon, RR
Timmermans, HA
Uchida, BT
Petersen, BD
Benner, KG
Rabkin, J
Keller, FS
机构
[1] OREGON HLTH SCI UNIV,DOTTER INTERVENT INST,PORTLAND,OR 97201
[2] OREGON HLTH SCI UNIV,DEPT MED,DIV GASTROENTEROL,PORTLAND,OR 97201
[3] OREGON HLTH SCI UNIV,DEPT SURG,DIV LIVER TRANSPLANTAT,PORTLAND,OR 97201
关键词
liver; interventional procedure; shunts; portosystemic; stents and prostheses;
D O I
10.1016/S1051-0443(97)70606-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the clinical and technical results of stent-graft placement for revision of transjugular intrahepatic portosystemic shunt (TIPS) stenoses and occlusions. MATERIALS AND METHODS: Six patients who developed recurrent TIPS stenosis or occlusion of the parenchymal tract underwent shunt revision with use of polytetrafluoroethylene (PTFE) stent-grafts anchored at both ends by Z stents and centrally supported by Wallstents. RESULTS: Before graft placement, mean primary patency was 50 days (range, 9-100 days), Patients underwent one to eight revisions with angioplasty or stent placement (mean, 3.2). Three patients had biliary-TIPS fistulas documented with use of a prototype double occlusion balloon catheter. Stent-grafts were successfully placed within the obstructed shunt, creating an excellent lumen in all cases, The portosystemic gradient was decreased from a mean of 24.3 mm Hg (range, 12-35 mm Hg) to a mean of 10.3 mm Hg (range, 7-16 mm Hg). Five of six patients were asymptomatic and no complications occurred (median clinical follow-up, 331 days), One patient died of pre-existing multi-organ system failure, The duration of primary patency after stent-grafting was improved (mean, 229 days; range, 27-324 days) and the difference approached statistical significance despite the small sample size (P = .056, paired t test), Three patients remained primarily patent at a mean venographic follow-up of 315 days, One shunt occluded at 1 month from residual thrombus in the portal vein, and one stenosis occurred that was secondary to misplacement of the original stent-graft, Patency was re-established in each of these patients. CONCLUSION: PTFE covered stent-grafts are effective for shunt revision in patients with tract stenosis or occlusion and appear to improve TIPS patency.
引用
收藏
页码:539 / 548
页数:10
相关论文
共 29 条
  • [1] TIPS: Short- and long-term results: A survey of 1750 patients
    Barton, RE
    Rosch, J
    Saxon, RR
    Lakin, PC
    Petersen, BD
    Keller, FS
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 1995, 12 (04) : 364 - 367
  • [2] Cabera J, 1996, GASTROENTEROLOGY, V110, P832
  • [3] CELLO JP, 1995, GASTROENTEROLOGY, V108, pA1045
  • [4] MULTICENTER INVESTIGATION OF THE ROLE OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT IN MANAGEMENT OF PORTAL-HYPERTENSION
    COLDWELL, DM
    RING, EJ
    REES, CR
    ZEMEL, G
    DARCY, MD
    HASKAL, ZJ
    MCKUSICK, MA
    GREENFIELD, AJ
    [J]. RADIOLOGY, 1995, 196 (02) : 335 - 340
  • [5] DOLMATCH BL, 1966, JVIR, V7, P641
  • [6] TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT STENOSIS AND REVISION - EARLY AND MIDTERM RESULTS
    HASKAL, ZJ
    PENTECOST, MJ
    SOULEN, MC
    SHLANSKYGOLDBERG, RD
    BAUM, RA
    COPE, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) : 439 - 444
  • [7] CRITICAL-APPRAISAL OF THE ANGIOGRAPHIC PORTACAVAL-SHUNT (TIPS)
    HELTON, WS
    BELSHAW, A
    ALTHAUS, S
    PARK, S
    COLDWELL, D
    JOHANSEN, K
    [J]. AMERICAN JOURNAL OF SURGERY, 1993, 165 (05) : 566 - 571
  • [8] Transjugular intrahepatic portosystemic stent-shunt (TIPSS) occlusion and the role of biliary venous fistulae
    Jalan, R
    Harrison, DJ
    Redhead, DN
    Hayes, PC
    [J]. JOURNAL OF HEPATOLOGY, 1996, 24 (02) : 169 - 176
  • [9] Kowligi R R, 1993, J Biomater Appl, V7, P353, DOI 10.1177/088532829300700403
  • [10] LaBerge J M, 1993, J Vasc Interv Radiol, V4, P779, DOI 10.1016/S1051-0443(93)71972-7