The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [41] DEVELOPMENTS IN THE QUANTITATIVE AND SEMIQUANTITATIVE DETERMINATION OF TRACE-ELEMENTS IN CARBONATES BY LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    PEARCE, NJG
    PERKINS, WT
    FUGE, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) : 595 - 598
  • [42] Isotopic analysis of plutonium in foods by inductively-coupled plasma mass spectrometry
    Emanuele, Kathryn
    Lin, Zhichao
    Healey, Stephanie
    Shareef, Abdur-Rafay
    Regan, Patrick
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 40 - 43
  • [43] Strontium isotopic analysis of environmental microsamples by inductively coupled plasma - tandem mass spectrometry
    Bertinetti, Stefano
    Bolea-Fernandez, Eduardo
    Malandrino, Mery
    Moroni, Beatrice
    Cappelletti, David
    Grotti, Marco
    Vanhaecke, Frank
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (01) : 103 - 113
  • [44] Improvements in 230Th dating, 230Th and 234U half-life values, and U-Th isotopic measurements by multi-collector inductively coupled plasma mass spectrometry
    Cheng, Hai
    Edwards, R. Lawrence
    Shen, Chuan-Chou
    Polyak, Victor J.
    Asmerom, Yemane
    Woodhead, Jon
    Hellstrom, John
    Wang, Yongjin
    Kong, Xinggong
    Spoetl, Christoph
    Wang, Xianfeng
    Alexander, E. Calvin, Jr.
    EARTH AND PLANETARY SCIENCE LETTERS, 2013, 371 : 82 - 91
  • [45] Direct analysis of dried blood spots by femtosecond-laser ablation-inductively coupled plasma-mass spectrometry. Feasibility of split-flow laser ablation for simultaneous trace element and isotopic analysis
    Aramendia, M.
    Rello, L.
    Berail, S.
    Donnard, A.
    Pecheyran, C.
    Resano, M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) : 296 - 309
  • [46] High-precision in situ silicon isotopic analyses by multi-collector secondary ion mass spectrometry in olivine and low-calcium pyroxene
    Villeneuve, Johan
    Chaussidon, Marc
    Marrocchi, Yves
    Deng, Zhengbin
    Watson, E. Bruce
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (20) : 1589 - 1597
  • [47] High-precision analysis of Sr/Ca and Mg/Ca ratios in corals by laser ablation inductively coupled plasma optical emission spectrometry
    Deng, Wenfeng
    Liu, Ying
    Wei, Gangjian
    Li, Xianhua
    Tu, Xianglin
    Xie, Luhua
    Zhang, Hong
    Sun, Weidong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (01) : 84 - 87
  • [48] Allanite U-Th-Pb geochronology by laser ablation inductively coupled plasma mass spectrometry: Evaluation and development of reference materials with low common Pb
    Luo, Tao
    Li, Mufei
    Deng, Xiaodong
    Tu, Jiarun
    Shen, Hongtao
    Kapitany, Tom
    Hu, Beining
    Zhang, Wen
    Hu, Zhaochu
    CHEMICAL GEOLOGY, 2025, 674
  • [49] A new high-precision method for determining stable chlorine isotopes in halite and igneous rock samples using UV-femtosecond laser ablation multiple Faraday collector inductively coupled plasma mass spectrometry
    Toyama, Chiaki
    Kimura, Jun-Ichi
    Chang, Qing
    Vaglarov, Bogdan Stefanov
    Kuroda, Junichiro
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (10) : 2194 - 2207
  • [50] Analysis of metal ion impurity in tetraethyl orthosilicate by sector field inductively coupled plasma mass spectrometry
    Lu, Chien-Wei
    Hung, Huan-Yi
    Lin, Wen-Lung
    Wu, Shu-Pao
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 149 : 243 - 248