The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [31] QUANTITATIVE-ANALYSIS OF TRACE-ELEMENTS IN CARBONATES USING LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    PERKINS, WT
    FUGE, R
    PEARCE, NJG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) : 445 - 449
  • [32] High-precision in situ analysis of Pb isotopes in glasses using 1013 Ω resistor high gain amplifiers with ultraviolet femtosecond laser ablation multiple Faraday collector inductively coupled plasma mass spectrometry
    Kimura, Jun-Ichi
    Chang, Qing
    Kanazawa, Nobuyuki
    Sasaki, Satoshi
    Vaglarov, Bogdan Stefanov
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (03) : 790 - 800
  • [33] Deciphering the uranium isotopic signature of coastal water and sediments from Tokyo Bay using a multi-collector inductively coupled plasma mass spectrometer
    Yamamoto, Kota
    Ohno, Takeshi
    Kitamura, Gou
    Takahashi, Hiroaki
    Hirata, Takafumi
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2024, 36
  • [34] Determination of Boron Isotope Ratios in Tooth Enamel by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) After Matrix Separation by Ion Exchange Chromatography
    He, Maoyong
    Jin, Zhangdong
    Luo, Chongguang
    Deng, Li
    Xiao, Jun
    Zhang, Fei
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (05) : 949 - 954
  • [35] The absolute isotopic composition and atomic weight of ytterbium using multi-collector inductively coupled plasma mass spectrometry and development of an SI-traceable ytterbium isotopic certified reference material
    Wang, Jun
    Ren, Tongxiang
    Lu, Hai
    Zhou, Tao
    Zhou, Yuanjing
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (06) : 1377 - 1385
  • [36] Evaluation of Optimized Procedures for High-Precision Lead Isotope Analyses of Seawater by Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Griffiths, Alex
    Packman, Hollie
    Leung, Yee-Lap
    Coles, Barry J.
    Kreissig, Katharina
    Little, Susan H.
    van de Flierdt, Tina
    Rehkamper, Mark
    ANALYTICAL CHEMISTRY, 2020, 92 (16) : 11232 - 11241
  • [37] Application of 1013 ohm Faraday cup current amplifiers for boron isotopic analyses by solution mode and laser ablation multicollector inductively coupled plasma mass spectrometry
    Lloyd, Nicholas S.
    Sadekov, Aleksey Yu.
    Misra, Sambuddha
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (01) : 9 - 18
  • [38] A novel approach to measure isotope ratios via multi-collector-inductively coupled plasma-mass spectrometry based on sample mixing with a non-enriched standard
    Costas-Rodriguez, Marta
    Lobo, Lara
    Vanhaecke, Frank
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (18) : 4393 - 4399
  • [39] High spatial resolution quantitative elemental imaging of foraminifer by laser ablation-inductively coupled plasma-mass spectrometry
    Ke, Yuqiu
    Zhou, Jianzong
    Qiao, Lei
    Zhang, Muhui
    Guo, Wei
    Jin, Lanlan
    Hu, Shenghong
    ANALYTICAL METHODS, 2019, 11 (16) : 2129 - 2137
  • [40] In situ Sr isotope measurement of small glass samples using multiple-Faraday collector inductively coupled plasma mass spectrometry with 1012 Ω resistor high gain Faraday amplifiers
    Chang, Qing
    Kimura, Jun-Ichi
    Vaglarov, Bogdan Stefanov
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (02) : 515 - 524