Distribution systems high impedance fault location: A spectral domain model considering parametric error processing

被引:32
作者
Nunes, J. U. N. [1 ]
Bretas, A. S. [2 ]
Bretas, N. G. [3 ]
Herrera-Orozco, A. R. [4 ]
Iurinic, L. U. [5 ]
机构
[1] Southern Fed Inst Educ Sci & Technol, Dept Elect Engn, BR-96015140 Pelotas, RS, Brazil
[2] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[3] Univ Sao Paulo, Dept Elect & Comp Engn, BR-13560480 Sao Carlos, SP, Brazil
[4] Technol Univ Pereira, Dept Elect Engn, Pereira 660003, Risaralda, Colombia
[5] Univ Reg Integrada Alto Uruguai & Missoes, Dept Comp Sci & Engn, BR-98400000 Frederico Westphalen, RS, Brazil
关键词
High-impedance fault; Fault location; Apparent impedance-based method; Least square method; Parametric error processing; ENHANCED PROTECTION SCHEME; LONG ARC; DISTANCE ESTIMATION; CIRCUIT ANALYSIS; IDENTIFICATION; ALGORITHM; DIAGNOSIS; LINES; AIR;
D O I
10.1016/j.ijepes.2019.02.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High impedance faults create specific technical challenges in the context of power system protection. The initial challenge is to detect these faults. If the fault is detected successfully, maintenance actions must be taken to avoid further risk to the population. The following technical challenge after detection is the location of these faults, which contributes significantly to the fast and safe restoration of the system. Although high impedance faults location is a topic of great concern, few studies are specifically devoted to this subject. This work presents an analytical formulation for the high impedance faults location in distribution systems. Initially, a system model which incorporates specific characteristics of this fault type is developed in the spectral domain. Using this model, the fault distance is estimated through a weighted least squares estimator associated with a parametric error processing algorithm. This algorithm detects the presence of parameter errors based on the composed measurement error in normalized form and further corrects the model. The validation of the presented technique is evaluated through comparative case studies considering the IEEE 13 node test feeder modeled in the Alternative Transient Program. Test results are encouraging indicating the formulation's potential for real-life applications.
引用
收藏
页码:227 / 241
页数:15
相关论文
共 51 条
  • [1] Abur A, 2009, STATE ESTIMATION ELE, P127
  • [2] Aguirre LA, 2015, INTRO IDENTIFICACAO
  • [3] [Anonymous], 2009, COMPUTER RELAYING PO
  • [4] [Anonymous], STATE ESTIMATION ELE
  • [5] [Anonymous], WSEAS INT C POW SYST
  • [6] DETECTION OF DISTRIBUTION HIGH IMPEDANCE FAULTS USING BURST NOISE SIGNALS NEAR 60 HZ
    AUCOIN, M
    RUSSELL, BD
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1987, 2 (02) : 342 - 348
  • [7] Tree-related high impedance fault location using phase shift measurement of high frequency magnetic field
    Bahador, Nooshin
    Namdari, Farhad
    Matinfar, Hamid Reza
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 100 : 531 - 539
  • [8] High impedance fault location in 11 kV underground distribution systems using wavelet transforms
    Bakar, A. H. A.
    Ali, M. S.
    Tan, ChiaKwang
    Mokhlis, H.
    Arof, H.
    Illias, H. A.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 55 : 723 - 730
  • [9] Bonneville power administration, 2007, ALT TRANS PROGR
  • [10] Bretas A.S., 2006, 2006 IEEE PES TRANSM, P1, DOI DOI 10.1109/TDCLA.2006.311611