Effects of treatment with oral appliance on 24-h blood pressure in patients with obstructive sleep apnea and hypertension: a randomized clinical trial

被引:64
作者
Andren, Ann [1 ]
Hedberg, Par [2 ,3 ]
Walker-Engstrom, Marie-Louise [2 ]
Wahlen, Petra [3 ]
Tegelberg, Ake [1 ,2 ,4 ]
机构
[1] Vastmanland Cty Hosp, Dept Stomatognath Physiol, S-72981 Vasteras, Sweden
[2] Uppsala Univ, Vastmanland Cty Hosp, Clin Res Ctr, Vasteras, Sweden
[3] Vastmanland Cty Hosp, Dept Clin Physiol, S-72981 Vasteras, Sweden
[4] Malmo Univ, Fac Odontol, Dept Stomatognath Physiol, Malmo, Sweden
关键词
Hypertension; Mandibular advancement; Obstructive sleep apnea; Oral appliance; RCT; POSITIVE AIRWAY PRESSURE; CORONARY HEART-DISEASE; RISK-FACTOR; MANDIBULAR ADVANCEMENT; DENTAL APPLIANCE; CARDIOVASCULAR-DISEASE; FOLLOW-UP; STROKE; ASSOCIATION; HYPOPNEA;
D O I
10.1007/s11325-012-0746-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Continuous positive airway pressure treatment has been shown to lower blood pressure (BP) in patients with obstructive sleep apnea (OSA). The aims of the present pilot study were to evaluate the potential effects of oral appliance (OA) therapy on BP, to assess various outcome BP measures, and to inform sample size calculation. Seventy-two patients with OSA and hypertension were randomly assigned to intervention with either an OA with mandibular advancement (active group) or an OA without advancement (control group). Before and after 3 months of treatment, the patients underwent nocturnal somnographic registration and 24-h ambulatory BP monitoring. Among the various BP measures, the largest trend toward effect of OA treatment was seen in 24-h mean systolic BP with a 1.8 mmHg stronger BP reduction in the active group compared with controls. A stronger trend toward effect was seen in a subgroup with baseline ambulatory daytime mean systolic BP > 135/85 mmHg where the mean systolic BP fell, on average, 2.6 mmHg. Additional exclusion of patients with baseline apnea hypopnea index (AHI) a parts per thousand currency sign15 gave a significant reduction in mean systolic BP of 4.4 mmHg (P = 0.044) in the active group compared with controls. In patients with OSA and hypertension, OA treatment had a modest trend toward effect on reducing BP. A stronger trend toward treatment effect was seen after excluding patients with normal baseline ambulatory BP. Additional exclusion of patients with baseline AHI a parts per thousand currency sign15 showed a significant treatment effect. Data to inform sample size for an adequately powered randomized study are provided.
引用
收藏
页码:705 / 712
页数:8
相关论文
共 37 条
  • [1] Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial
    Aarab, Ghizlane
    Lobbezoo, Frank
    Hamburger, Hans L.
    Naeije, Machiel
    [J]. RESPIRATION, 2011, 81 (05) : 411 - 419
  • [2] Effects on blood pressure after treatment of obstructive sleep apnoea with a mandibular advancement appliance - a three-year follow-up
    Andren, A.
    Sjoquist, M.
    Tegelberg, A.
    [J]. JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 719 - 725
  • [3] [Anonymous], 2004, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD004435.PUB2
  • [4] Effect of nocturnal nasal continuous positive airway pressure on blood pressure in obstructive sleep apnea
    Bazzano, Lydia A.
    Khan, Zia
    Reynolds, Kristi
    He, Jiang
    [J]. HYPERTENSION, 2007, 50 (02) : 417 - 423
  • [5] Prevalence of sleep-disordered breathing in women - Effects of gender
    Bixler, EO
    Vgontzas, AN
    Lin, HM
    Ten Have, T
    Rein, J
    Vela-Bueno, A
    Kales, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (03) : 608 - 613
  • [6] BLOOD-PRESSURE, STROKE, AND CORONARY HEART-DISEASE .2. SHORT-TERM REDUCTIONS IN BLOOD-PRESSURE - OVERVIEW OF RANDOMIZED DRUG TRIALS IN THEIR EPIDEMIOLOGIC CONTEXT
    COLLINS, R
    PETO, R
    MACMAHON, S
    HEBERT, P
    FIEBACH, NH
    EBERLEIN, KA
    GODWIN, J
    QIZILBASH, N
    TAYLOR, JO
    HENNEKENS, CH
    [J]. LANCET, 1990, 335 (8693) : 827 - 838
  • [7] ARTERIAL BLOOD-PRESSURE RESPONSES TO GRADED TRANSIENT AROUSAL FROM SLEEP IN NORMAL HUMANS
    DAVIES, RJO
    BELT, PJ
    ROBERTS, SJ
    ALI, NJ
    STRADLING, JR
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (03) : 1123 - 1130
  • [8] Randomized placebo-controlled trial of continuous positive airway pressure on blood pressure in the sleep apnea-hypopnea syndrome
    Faccenda, JF
    MacKay, TW
    Boon, NA
    Douglas, NJ
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (02) : 344 - 348
  • [9] Franklin K., 2007, Obstructive sleep apnoea syndrome. Report of a joint Nordic project
  • [10] Oral appliance therapy reduces blood pressure in obstructive sleep apnea: A randomized, controlled trial
    Gotsopoulos, H
    Kelly, JJ
    Cistulli, PA
    [J]. SLEEP, 2004, 27 (05) : 934 - 941