Thermal performance impacts of heat spreading lids on flip chip packages: With and without heat sinks

被引:20
作者
Wakil, J [1 ]
机构
[1] IBM Corp, Hopewell Jct, NY 12533 USA
关键词
D O I
10.1016/j.microrel.2005.01.007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Heat spreading lids on a flip chip package can provide many thermal and mechanical advantages. Major drawbacks are higher module costs and potentially poorer thermal performance with a heat sink. This study compares thermal performance of direct lid attach (DLA) and bare die flip chip packages and addresses the roles of interface resistance and lid thickness. The IBM SLC (TM) package is tested and modeled. JEDEC standard wind tunnel tests as well as CFD models are used for analysis. The study reveals that the DLA design without additional heat sinking can provide significantly better thermal performance compared to the bare die package, depending on package size and,airflow rate. With a heat sink the performance of the lidded package can be superior or inferior depending on interface resistance, lid design and the standard used for comparison. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:380 / 385
页数:6
相关论文
共 9 条
[1]  
ANDO H, P 1999 EL COMP TECHN, P227
[2]  
DOLBEAR TP, P 1997 INT SYST PACK, P279
[3]  
*EIA JEDEC, 1999, 516 EIA JEDEC
[4]  
*EIA JEDEC, 1995, 512 EIA JEDEC
[5]  
*EIA JEDEC, 2000, 519 EIA JEDEC
[6]   An investigation of thermal enhancement on flip chip plastic BGA packages using CFD tool [J].
Lee, TYT .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2000, 23 (03) :481-489
[7]  
Panton R., 1996, INCOMPRESSIBLE FLOW, P129
[8]  
STARR O, P 1999 EL COMP TECHN, P238
[9]  
WAKIL J, 2001, COMPARISON IBM ENDIC