Optimized chemical coverage and data quality for non-targeted screening applications using liquid chromatography/high-resolution mass spectrometry

被引:34
作者
Knolhoff, Ann M. [1 ]
Kneapler, Caitlin N. [1 ]
Croley, Timothy R. [1 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, 5001 Campus Dr, College Pk, MD 20740 USA
关键词
Non-targeted screening; Liquid chromatography/high-resolution mass spectrometry; Sample preparation; Resolving power; Polarity switching; Data quality; PESTICIDE-RESIDUES; SAMPLE PREPARATION; CONTAMINANTS; EXTRACTION; PHASE;
D O I
10.1016/j.aca.2019.03.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-targeted small molecule screening methods are used to analyze samples for potential compounds of interest without focusing on specific molecular species. There is great interest in these methods for metabolomic, environmental, forensic, and food safety applications, among others, to determine compounds that are responsible for a particular disease state or the presence of a harmful compound. In order for non-targeted analyses to become standardized and routine, best practices for sample preparation, data collection, and data analysis must be determined. This work focuses on optimizing specific aspects of a non-targeted workflow that utilizes high-resolution mass spectrometry using an Orbitrap instrument coupled to liquid chromatography. Sample preparation, liquid chromatography gradient length, and mass spectrometry resolving power and ionization modes were investigated to determine optimal conditions for detecting and extracting compounds from the data that cover broad molecular and polarity ranges. Infant rice cereal, orange juice, and yogurt with spiked standards were analyzed; food is inherently challenging to analyze due in part to sample complexity and diversity. Of the conditions tested, optimal conditions included a generic sample extraction using acetonitrile, water, and formic acid, a 25 min chromatographic gradient, collecting data in both positive and negative ion modes, and using 70 k resolving power. There are of course tradeoffs associated with each of these options that will be described in detail so that the appropriate conditions can be chosen for the desired application. Published by Elsevier B.V.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 24 条
[1]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[2]   Sample preparation and orthogonal chromatography for broad polarity range plasma metabolomics: Application to human subjects with neurodegenerative dementia [J].
Armirotti, Andrea ;
Basit, Abdul ;
Realini, Natalia ;
Caltagirone, Carlo ;
Bossu, Paola ;
Spalletta, Gianfranco ;
Piomelli, Daniele .
ANALYTICAL BIOCHEMISTRY, 2014, 455 :48-54
[3]   Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry [J].
Boudah, Samia ;
Olivier, Marie-Francoise ;
Aros-Calt, Sandrine ;
Oliveira, Lydie ;
Fenaille, Francois ;
Tabet, Jean-Claude ;
Junot, Christophe .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 966 :34-47
[4]   Non-targeted detection of chemical contamination in carbonated soft drinks using NMR spectroscopy, variable selection and chemometrics [J].
Charlton, Adrian J. ;
Robb, Paul ;
Donarski, James A. ;
Godward, John .
ANALYTICA CHIMICA ACTA, 2008, 618 (02) :196-203
[5]   Combining targeted and nontargeted data analysis for liquid chromatography/high-resolution mass spectrometric analyses [J].
Croley, Timothy R. ;
White, Kevin D. ;
Wong, Jon ;
Callahan, John H. ;
Musser, Steven M. ;
Antler, Margaret ;
Lashin, Vitaly ;
McGibbon, Graham A. .
JOURNAL OF SEPARATION SCIENCE, 2013, 36 (05) :971-979
[6]   The Chromatographic Role in High Resolution Mass Spectrometry for Non-Targeted Analysis [J].
Croley, Timothy R. ;
White, Kevin D. ;
Callahan, John H. ;
Musser, Steven M. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (09) :1569-1578
[7]   Evaluation of a rapid screening method for chemical contaminants of concern in four food-related matrices using QuEChERS extraction, UHPLC and high resolution mass spectrometry [J].
Filigenzi, Michael S. ;
Ehrke, Nanette ;
Aston, Linda S. ;
Poppenga, Robert H. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (10) :1324-1339
[8]   Olive oil authenticity studies by target and nontarget LC-QTOF-MS combined with advanced chemometric techniques [J].
Kalogiouri, Natasa P. ;
Alygizakis, Nikiforos A. ;
Aalizadeh, Reza ;
Thomaidis, Nikolaos S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (28) :7955-7970
[9]   Non-targeted detection of milk powder adulteration using Raman spectroscopy and chemometrics: melamine case study [J].
Karunathilaka, Sanjeewa R. ;
Farris, Samantha ;
Mossoba, Magdi M. ;
Moore, Jeffrey C. ;
Yakes, Betsy Jean .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (02) :170-182
[10]   Interferences and contaminants encountered in modern mass spectrometry [J].
Keller, Bernd O. ;
Suj, Jie ;
Young, Alex B. ;
Whittal, Randy M. .
ANALYTICA CHIMICA ACTA, 2008, 627 (01) :71-81