An audit of using the H Pipelle for endometrial sampling at outpatient hysteroscopy and literature review comparison with the Pipelle de Cornier

被引:15
作者
Dacco', Maria Diletta [1 ]
Moustafa, Mohsen
Papoutsis, Dimitrios
Georgantzis, Dimitrios
Halmos, Gabor
Magos, Adam
机构
[1] Royal Free Hosp, Minimally Invas Therapy Unit, London NW3 2QG, England
关键词
Hysteroscopy; H Pipelle; Endometrial biopsy; VABRA ASPIRATOR; BIOPSY; DEVICE; CURETTE;
D O I
10.1016/j.ejogrb.2012.07.021
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To analyse the efficiency of the H Pipelle endometrial sampler at "no touch" (vaginoscopic) diagnostic hysteroscopy in terms of biopsy adequacy for histological diagnosis. Study design: Retrospective descriptive study of 200 premenopausal women including comparison with previously published data on traditional biopsy instruments. Results: Biopsy was adequate in 82% of cases overall, rising to 87% in those without submucous fibroids or polyps. Comparison with published data on other biopsy instruments shows that the H Pipelle is at least as efficient. Conclusion: The H Pipelle appears to be at least as effective as traditional endometrial samplers even after hysteroscopy but allows hysteroscopy and biopsy to be done using a purely "no touch" (vaginoscopic) technique. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:299 / 301
页数:3
相关论文
共 34 条
[1]   Endometrial biopsy during outpatient hysteroscopy: evaluation and comparison of two devices [J].
Agostini, A ;
Shojai, R ;
Cravello, L ;
Rojat-Habib, MC ;
Roger, V ;
Bretelle, F ;
Blanc, B .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2001, 97 (02) :220-222
[2]   Comparison of cytospat and pipelle endometrial biopsy instruments [J].
Antoni, J ;
Folch, E ;
Costa, J ;
Foradada, CM ;
Cayuela, E ;
Combalia, N ;
Rue, M .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 (01) :57-61
[3]   Ambulatory hysteroscopy: evidence-based guide to diagnosis and therapy [J].
Bakour, Shagaf H. ;
Jones, Sian E. ;
O'Donovan, Peter .
BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2006, 20 (06) :953-975
[4]   Endometrial biopsy: A pilot study of instrument used; Pipelle vs infant feeding tube [J].
Bhide, A. ;
Gangji, A. ;
Anyanwu, L. .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 27 (08) :838-839
[5]   Vaginoscopic approach to outpatient hysteroscopy: a systematic review of the effect on pain [J].
Cooper, N. A. M. ;
Smith, P. ;
Khan, K. S. ;
Clark, T. J. .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 117 (05) :532-539
[6]   Local anaesthesia for pain control during outpatient hysteroscopy: systematic review and meta-analysis [J].
Cooper, Natalie A. M. ;
Khan, Khalid S. ;
Clark, T. Justin .
BMJ-BRITISH MEDICAL JOURNAL, 2010, 340 :748
[7]   THE PIPELLE - A DISPOSABLE DEVICE FOR ENDOMETRIAL BIOPSY [J].
CORNIER, E .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (01) :109-110
[8]   PIPELLE - A MORE ACCEPTABLE TECHNIQUE FOR OUTPATIENT ENDOMETRIAL BIOPSY [J].
EDDOWES, HA ;
READ, MD ;
CODLING, BW .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (10) :961-962
[9]  
Elsandabesee D, 2005, J Obstet Gynaecol, V25, P32, DOI 10.1080/01443610400025390
[10]  
Fakhar S, 2008, ANN SAUDI MED, V28, P188