Background and purpose Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. Patients and methods In a prospective, parallel-group, randomized patient-blinded clinical trial, we included 32 hands in 28 patients (5 males) with a mean age of 58 (40-77) years and with Eaton stage-2 or -3 osteoarthritis of the trapeziometacarpal joint. Patients were randomized to surgery with a cemented DLC all-polyethylene cup (C) (n = 16) or an uncemented hydroxyapatite-coated chrome-cobalt Elektra screw cup (UC) (n = 16). Uncemented cups were inserted without threading of the bone. Stereoradiographs for evaluation of cup migration (primary effect size) and DASH and pain scores were obtained during 2 years of follow-up. Results The 2-year total translation (TT) was similar (p = 0.2): 0.24 mm (SD 0.10) for the C (n = 11) and 0.19 mm (SD 0.16) for the UC (n = 11). Variances were similar (p = 0.4). Judged by RSA, 2 UC cups and 1 C cup became loose (TT > 1 mm). Both UC cups were found to be loose at revision. Grip strength, pain, and DASH scores were similar between groups at all measurement points. Interpretation Early implant fixation and clinical outcome were equally good with both cup designs. This is the first clinical RSA study on trapezium cups, and the method appears to be clinically useful for detection of loose implants.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 30 条
  • [1] Fixed or loose? Dichotomy in RSA data for cemented cups
    Aspenberg, Per
    Wagner, Philippe
    Nilsson, Kjell G.
    Ranstam, Jonas
    [J]. ACTA ORTHOPAEDICA, 2008, 79 (04) : 467 - 473
  • [2] TOTAL JOINT REPLACEMENT AT THE BASE OF THE THUMB - PRELIMINARY-REPORT
    BRAUN, RM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1982, 7 (03): : 245 - 251
  • [3] How many patients? How many limbs? Analysis of patients or limbs in the orthopaedic literature: Asystematic review
    Bryant, D
    Havey, TC
    Roberts, R
    Guyatt, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) : 41 - 45
  • [4] TRAPEZIO-METACARPAL ARTHROPLASTY BY TOTAL PROSTHESIS
    CAFFINIERE, JYDL
    AUCOUTURIER, P
    [J]. HAND, 1979, 11 (01): : 41 - 46
  • [5] COONEY WP, 1987, CLIN ORTHOP RELAT R, P35
  • [6] BIOMECHANICAL ANALYSIS OF STATIC FORCES IN THUMB DURING HAND FUNCTION
    COONEY, WP
    CHAO, EYS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) : 27 - 36
  • [7] EATON RG, 1987, HAND CLIN, V3, P455
  • [8] HIGH LOOSENING RATE OF THE MOJE ACAMO PROSTHESIS FOR TREATING OSTEOARTHRITIS OF THE TRAPEZIOMETACARPAL JOINT
    Hansen, T. B.
    Vainorius, D.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (05) : 571 - 574
  • [9] Primary cup fixation with different designs of trapeziometacarpal total joint trapezium components: a radiostereometric analysis in a pig bone model
    Hansen, T. B.
    Meier, M.
    Moller, M. C. M.
    Larsen, K.
    Stilling, M.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (04) : 285 - 290
  • [10] TRAPEZIOMETACARPAL JOINT IMPLANTS CAN BE EVALUATED BY ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    Hansen, T. B.
    Larsen, K.
    Bjergelund, L.
    Stilling, M.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (06) : 480 - 485