Fracture resistance after implantoplasty in three implant-abutment connection designs

被引:20
作者
Camps-Font, Octavi [1 ]
Gonzalez-Barnadas, Albert [1 ]
Mir-Mari, Javier [1 ]
Figueiredo, Rui [1 ]
Gay-Escoda, Cosme [1 ]
Valmaseda-Castellon, Eduard [1 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, Spain
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2020年 / 25卷 / 05期
关键词
Dental implants; narrow diameter; implant connection; peri-implantitis; implantoplasty; fracture strength; ADVANCED PERI-IMPLANTITIS; 3-YEAR CLINICAL-TRIAL; SHAPED ORAL IMPLANTS; SURFACE-ROUGHNESS; RESECTIVE SURGERY; BIOFILM FORMATION; PART II; DIAMETER; THERAPY; STRENGTH;
D O I
10.4317/medoral.23700
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty.
引用
收藏
页码:E691 / E699
页数:9
相关论文
共 30 条
[11]   Peri-implant diseases: diagnosis and risk indicators [J].
Heitz-Mayfield, Lisa J. A. .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :292-304
[12]   A systematic review of the 5-year survival and complication rates of implant-supported single crowns [J].
Jung, Ronald E. ;
Pjetursson, Bjarni E. ;
Glauser, Roland ;
Zembic, Anja ;
Zwahlen, Marcel ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (02) :119-130
[13]   Systematic Review on Success of Narrow-Diameter Dental Implants [J].
Klein, Marc O. ;
Schiegnitz, Eik ;
Al-Nawas, Bilal .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :43-54
[14]   Prevalences of peri-implantitis and peri-implant mucositis: systematic review and meta-analysis [J].
Lee, Chun-Teh ;
Huang, Yen-Wen ;
Zhu, Liang ;
Weltman, Robin .
JOURNAL OF DENTISTRY, 2017, 62 :1-12
[15]   Clinical and radiographic outcomes of a combined resective and regenerative approach in the treatment of peri-implantitis: a prospective case series [J].
Matarasso, Sergio ;
Siciliano, Vincenzo Iorio ;
Aglietta, Marco ;
Andreuccetti, Gianmaria ;
Salvi, Giovanni E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) :761-767
[16]  
Tribst JPM, 2017, BRAZ ORAL RES, V31
[17]  
Quirynen M, 1996, Int J Oral Maxillofac Implants, V11, P169
[18]   Surface roughness of dental implants and treatment time using six different implantoplasty procedures [J].
Ramel, Christian F. ;
Lussi, Anja ;
Ozcan, Mutlu ;
Jung, Ronald E. ;
Hammerle, Christoph H. F. ;
Thoma, Daniel S. .
CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (07) :776-781
[19]  
Rangert B, 1995, Int J Oral Maxillofac Implants, V10, P326
[20]   Therapy of peri-implantitis with resective surgery - A 3-year clinical trial on rough screw-shaped oral implants. Part I: clinical outcome [J].
Romeo, E ;
Ghisolfi, M ;
Murgolo, N ;
Chiapasco, M ;
Lops, D ;
Vogel, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (01) :9-18