Fracture resistance after implantoplasty in three implant-abutment connection designs

被引:20
作者
Camps-Font, Octavi [1 ]
Gonzalez-Barnadas, Albert [1 ]
Mir-Mari, Javier [1 ]
Figueiredo, Rui [1 ]
Gay-Escoda, Cosme [1 ]
Valmaseda-Castellon, Eduard [1 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, Spain
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2020年 / 25卷 / 05期
关键词
Dental implants; narrow diameter; implant connection; peri-implantitis; implantoplasty; fracture strength; ADVANCED PERI-IMPLANTITIS; 3-YEAR CLINICAL-TRIAL; SHAPED ORAL IMPLANTS; SURFACE-ROUGHNESS; RESECTIVE SURGERY; BIOFILM FORMATION; PART II; DIAMETER; THERAPY; STRENGTH;
D O I
10.4317/medoral.23700
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty.
引用
收藏
页码:E691 / E699
页数:9
相关论文
共 30 条
[1]   Implant survival and complications. The Third EAO consensus conference 2012 [J].
Albrektsson, T. ;
Donos, N. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 :63-65
[2]   Analysis of Implant Strength After Implantoplasty in Three Implant-Abutment Connection Designs: An In Vitro Study [J].
Alexandre Gehrke, Sergio ;
Aramburu Junior, Jaime Sarda ;
Dedavid, Berenice Anina ;
Shibli, Jamil Awad .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) :E65-E70
[3]   In vivo and in vitro biofilm formation on two different titanium implant surfaces [J].
Buergers, Ralf ;
Gerlach, Till ;
Hahnel, Sebastian ;
Schwarz, Frank ;
Handel, Gerhard ;
Gosau, Martin .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) :156-164
[4]   Impact of Implantoplasty on Strength of the Implant-Abutment Complex [J].
Chan, Hsun-Liang ;
Oh, Won-Suck ;
Ong, Hwei Sze ;
Fu, Jia-Hui ;
Steigmann, Marius ;
Sierraalta, Marianella ;
Wang, Hom-Lay .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) :1530-1535
[5]   Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants [J].
Costa-Berenguer, Xavier ;
Garcia-Garcia, Marta ;
Sanchez-Torres, Alba ;
Sanz-Alonso, Mariano ;
Figueiredo, Rui ;
Valmaseda-Castellon, Eduard .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) :46-54
[6]   Peri-implant health and disease. A systematic review of current epidemiology [J].
Derks, Jan ;
Tomasi, Cristiano .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2015, 42 :S158-S171
[7]  
Elter C, 2008, INT J ORAL MAX IMPL, V23, P327
[8]   Management of peri-implant mucositis and peri-implantitis [J].
Figuero, Elena ;
Graziani, Filippo ;
Sanz, Ignacio ;
Herrera, David ;
Sanz, Mariano .
PERIODONTOLOGY 2000, 2014, 66 (01) :255-273
[9]   Osseointegrated Implant Fracture: Causes and Treatment [J].
Gealh, Walter Cristiano ;
Mazzo, Valeria ;
Barbi, Francisco ;
Camarini, Edevaldo Tadeu .
JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) :499-503
[10]   Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study [J].
Gehrke, Sergio Alexandre ;
dos Santos Vianna, Miriam Souza ;
Dedavid, Berenice Anina .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) :715-720