Behavior of FRP-Steel Confined Concrete Tubular Columns Made of Expansive Self-Consolidating Concrete under Axial Compression

被引:53
作者
Cao, Qi [1 ,2 ]
Tao, Jinju [1 ]
Wu, Zhimin [1 ]
Ma, Zhongguo John [3 ,4 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[2] Ocean Engn Joint Res Ctr DUT UWA, Dalian 116024, Peoples R China
[3] Univ Tennessee, Dept Civil & Environm Engn, 313 John D Tickle Bldg, Knoxville, TN 37996 USA
[4] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber-reinforced polymer (FRP); Prestress; Columns; Expansive self-consolidating concrete (ESCC); Steel tube; STRESS-STRAIN MODEL; FLEXURAL BEHAVIOR; FIBER COMPOSITES; DESIGN; MEMBERS; BEAMS;
D O I
10.1061/(ASCE)CC.1943-5614.0000818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 32 fiber-reinforced polymer (FRP) confined concrete columns are manufactured and tested under axial compression including 8 FRP-confined solid columns (FCSCs), 4 FRP-confined concrete-filled steel tube columns (CCFTs), and 20 hybrid FRP-concrete-steel double-skin tubular columns (DSTCs). Key parameters include FRP layers, diameter of steel tube, and presence or absence of an expansive agent and concrete filling for the steel tube. Due to the effect of the expansive agent, prestress in concrete is detected in all specimens with expansive self-consolidating concrete (ESCC). For FCSCs and CCFTs, the normalized intercept, inflection and ultimate load for ESCC specimens are higher than those of self-consolidating concrete (SCC) specimens. For DSTCs, when the inner steel tube is filled with concrete only normalized ultimate loads are improved by in ESCC specimens compared with SCC specimens. For hollow DSTCs, however, an expansive agent does not improve the axial behavior. The number of layers of FRP show a positive influence on the normalized intercept, inflection, and ultimate load of ESCC FCSC specimens. In addition, test results for hollow DSTCs indicate that normalized ultimate loads decrease with the increase of steel tube diameter. An existing model used to predict the compressive strength and ultimate axial strain of FCSCs shows good agreement. (c) 2017 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 39 条
  • [1] Behavior of FRP-HSC-Steel Double-Skin Tubular Columns under Cyclic Axial Compression
    Albitar, Mohammad
    Ozbakkaloglu, Togay
    Fanggi, Butje Alfonsius Louk
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2015, 19 (02)
  • [2] [Anonymous], 2005, The European Guidelines for Self-Compacting Concrete Specification, Production and Use
  • [3] [Anonymous], 2014, A C1621
  • [4] ASTM, 2009, C1611C1611M ASTM
  • [5] ASTM, 2008, D30393039M ASTM
  • [6] Behavior in compression of concrete cylinders externally wrapped with basalt fibers
    Campione, G.
    La Mendola, L.
    Monaco, A.
    Valenza, A.
    Fiore, V.
    [J]. COMPOSITES PART B-ENGINEERING, 2015, 69 : 576 - 586
  • [7] Cao Q, 2011, ACI STRUCT J, V108, P592
  • [8] Behavior and Modeling of Concrete Confined with FRP Composites of Large Deformability
    Dai, Jian-Guo
    Bai, Yu-Lei
    Teng, J. G.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (06) : 963 - 973
  • [9] Design and analysis a novel RF MEMS switched capacitor for low pull-in voltage application
    Deng, Zhongliang
    Wei, Hao
    Fan, Sen
    Gan, Jun
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2016, 22 (08): : 2141 - 2149
  • [10] Behavior of SCC confined in short GFRP tubes
    El Chabib, H
    Nehdi, M
    El Naggar, MH
    [J]. CEMENT & CONCRETE COMPOSITES, 2005, 27 (01) : 55 - 64