Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer

被引:15
|
作者
Wang, Jingyi
Li, Ying
Jin, Yumei
Yang, Xue
Zhao, Chan
Long, Qin [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Ophthalmol, Beijing 100730, Peoples R China
基金
中国国家自然科学基金;
关键词
OCULAR RESPONSE ANALYZER; REFRACTIVE ERROR; INTRAOCULAR-PRESSURE; DEFORMATION RESPONSE; LASIK; SCLERA; SMILE; AGE;
D O I
10.1155/2015/161869
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the corneal biomechanical parameters in myopic and emmetropic eyes using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. 103 myopic and emmetropic eyes of 103 patients were examined. Corneal biomechanical parameters, axial length, and mean keratometry were measured using CorVis ST, IOL Master, and topography, respectively. Corneal biomechanical properties were compared within four groups. Bivariate correlation analysis was used to assess the relationship between corneal biomechanical parameters and ocular characteristics. Results. Four of ten corneal biomechanical parameters, namely, deformation amplitude (DA), first- and second-applanation time (A1-time, A2-time), and radius at highest concavity (HC radius), were significantly different within the four groups (P < 0.05). In correlation analysis, DA was positively correlated with axial length (r = 0.20, P = 0.04); A2-time was positively correlated with spherical equivalent (SE) (r = 0.24, P = 0.02); HC radius was positively correlated with SE (r = 0.24, P = 0.02) and was negatively correlated with mean keratometry (r = -0.20, P = 0.046) and axial length (r = -0.21, P = 0.03). Conclusions. The corneal refraction-related biomechanical alterations were associated with ocular characteristics. Highly myopic eyes exhibited longer DA and smaller HC radius than do moderately myopic eyes; the eyes with longer axial length tend to have less corneal stiffness and are easier to deform under stress.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    Yu, A-Yong
    Shao, Hui
    Pan, Anpeng
    Wang, Qinmei
    Huang, Zixu
    Song, Benhao
    McAlinden, Colm
    Huang, Jinhai
    Chen, Sisi
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [2] Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes
    Lee, Hun
    Kang, David Sung Yong
    Ha, Byoung Jin
    Choi, Jin Young
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    YONSEI MEDICAL JOURNAL, 2018, 59 (09) : 1115 - 1122
  • [3] Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer
    Maeda, Naoyuki
    Ueki, Ryotaro
    Fuchihata, Mutsumi
    Fujimoto, Hisataka
    Koh, Shizuka
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (06) : 483 - 489
  • [4] Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults
    Lee, Hun
    Kang, David Sung Yong
    Ha, Byoung Jin
    Choi, Jin Young
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Ha Yan
    Kim, Tae-im
    CORNEA, 2017, 36 (01) : 53 - 58
  • [5] Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer
    Herber, Robert
    Ramm, Lisa
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 778 - 788
  • [6] Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer
    Miki, Atsuya
    Maeda, Naoyuki
    Ikuno, Yasushi
    Asai, Tomoko
    Hara, Chikako
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (01) : 538 - 544
  • [7] Corneal biomechanical properties measured with the Ocular Response Analyser in a myopic population
    Plakitsi, Athina
    O'Donnell, Clare
    Miranda, Marco A.
    Charman, W. Neil
    Radhakrishnan, Hema
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (04) : 404 - 412
  • [8] Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology
    He, Miao
    Ding, Hui
    He, Hong
    Zhang, Chi
    Liu, Liangping
    Zhong, Xingwu
    BMC OPHTHALMOLOGY, 2017, 17
  • [9] Corneal Biomechanical Properties in High Myopia Measured by Dynamic Scheimpflug Imaging Technology
    He, Miao
    Wang, Wei
    Ding, Hui
    Zhong, Xingwu
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (12) : 1074 - 1080
  • [10] Evaluation of Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Eyes with Pterygium
    Kara, Necip
    Baz, Okkes
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 94 - 97