Precision of a New Tool to Measure Visceral Adipose Tissue (VAT) Using Dual-Energy X-Ray Absorptiometry (DXA)

被引:55
作者
Rothney, Megan P. [1 ]
Xia, Yi [2 ]
Wacker, Wynn K. [2 ]
Martin, Francois-Pierre [3 ]
Beaumont, Maurice [3 ]
Rezzi, Serge [3 ]
Giusti, Vittorio [4 ]
Ergun, David L. [2 ]
机构
[1] GE Global Res Ctr, Computat Biol & Biostat Lab, Niskayuna, NY USA
[2] GE Healthcare, Madison, WI USA
[3] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne, Switzerland
[4] CHU Vaudois, Dept Internal Med, CH-1011 Lausanne, Switzerland
关键词
BONE-MINERAL DENSITY; LUNAR IDXA DENSITOMETER; IN-VIVO PRECISION; BODY-COMPOSITION; WOMEN; ADULTS; FAT;
D O I
10.1002/oby.20140
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: A new tool to quantify visceral adipose tissue (VAT) over the android region of a total body dual-energy x-ray absorptiometry (DXA) scan has recently been reported. The measurement, CoreScan, is currently available on Lunar iDXA densitometers. The purpose of the study was to determine the precision of the CoreScan VAT measurement, which is critical for understanding the utility of this measure in longitudinal trials. Design and Methods: VAT precision was characterized in both an anthropomorphic imaging phantom (measured on 10 Lunar iDXA systems) and a clinical population consisting of obese women (n = 32). Results: The intrascanner precision for the VAT phantom across 9 quantities of VAT mass (01,800 g) ranged from 28.4 to 38.0 g. The interscanner precision ranged from 24.7 to 38.4 g. There was no statistical dependence on the quantity of VAT for either the inter-or intrascanner precision result (p = 0.670). Combining inter- and intrascanner precision yielded a total phantom precision estimate of 47.6 g for VAT mass, which corresponds to a 4.8% coefficient of variance (CV) for a 1 kg VAT mass. Our clinical population, who completed replicate total body scans with repositioning between scans, showed a precision of 56.8 g on an average VAT mass of 1110.4 g. This corresponds to a 5.1% CV. Hence, the in vivo precision result was similar to the phantom precision result. Conclusions: The study suggests that CoreScan has a relatively low precision error in both phantoms and obese women and therefore may be a useful addition to clinical trials where interventions are targeted towards changes in visceral adiposity.
引用
收藏
页码:E134 / E136
页数:3
相关论文
共 9 条
[1]  
Chen R, 2005, J BONE MINER RES, V20, pS220
[2]   Comparison of body weight and composition measured by two different dual energy X-ray absorptiometry devices and three acquisition modes in obese women [J].
Genton, Laurence ;
Karsegard, Veronique L. ;
Zawadynski, Sophie ;
Kyle, Ursula G. ;
Pichard, Claude ;
Golay, Alain ;
Hans, Didier B. .
CLINICAL NUTRITION, 2006, 25 (03) :428-437
[3]   In vivo precision of the GE Lunar iDXA densitometer for the measurement of total body composition and fat distribution in adults [J].
Hind, K. ;
Oldroyd, B. ;
Truscott, J. G. .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2011, 65 (01) :140-142
[4]   In vivo Precision of the GE Lunar iDXA Densitometer for the Measurement of Total-Body, Lumbar Spine, and Femoral Bone Mineral Density in Adults [J].
Hind, Karen ;
Oldroyd, Brian ;
Truscott, John G. .
JOURNAL OF CLINICAL DENSITOMETRY, 2010, 13 (04) :413-417
[5]   Dual-Energy X-Ray Absorptiometry for Quantification of Visceral Fat [J].
Kaul, Sanjiv ;
Rothney, Megan P. ;
Peters, Dawn M. ;
Wacker, Wynn K. ;
Davis, Cynthia E. ;
Shapiro, Michael D. ;
Ergun, David L. .
OBESITY, 2012, 20 (06) :1313-1318
[6]   Measurement precision of body composition variables using the Lunar DPX-L densitometer [J].
Kiebzak, GM ;
Leamy, LJ ;
Pierson, LM ;
Nord, RH ;
Zhang, ZY .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) :35-41
[7]   Effect of Precision on Longitudinal Follow-Up of Bone Mineral Density Measurements in Elderly Women and Men [J].
Lenora, Janaka ;
Akesson, Kristina ;
Gerdhen, Paul .
JOURNAL OF CLINICAL DENSITOMETRY, 2010, 13 (04) :407-412
[8]  
Mautalen C, 1996, MEDICINA-BUENOS AIRE, V56, P29
[9]   Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers - bone mineral density and body composition studies [J].
Oldroyd, B ;
Smith, AH ;
Truscott, JG .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (08) :977-987