The purpose of this study is to develop a radiation distribution monitor using a normal plastic optical fiber. The monitor has a long operating length and can obtain continuous radiation distributions. A principle of the position sensing is based on a time-of-flight technique. The monitor is sensitive to beta rays or charged particles, gamma rays, and fast neutrons. The spatial resolutions for beta-rays (Sr-90-Y-90), gamma-rays (Cs-137), and D-T neutrons are 30,37, and 13 cm, respectively. The detection efficiencies for the beta-rays, gamma-rays, and D-T neutrons are 0.11%, 1.6 X 10(-5)% and 1.2 x 10(-4)%, respectively. The effective attenuation length of the detection efficiency is 18 m. In this paper, we describe the basic characteristics of this monitor.