A Comparison of the Corrected Intraocular Pressure Obtained by the Corvis ST and Reichert 7CR Tonometers in Glaucoma Patients

被引:12
|
作者
Nakao, Yoshitaka [1 ]
Kiuchi, Yoshiaki [1 ]
Okimoto, Satoshi [1 ]
机构
[1] Hiroshima Univ, Ophthalmol & Visual Sci Dept, Hiroshima, Japan
来源
PLOS ONE | 2017年 / 12卷 / 01期
关键词
OCULAR RESPONSE ANALYZER; CENTRAL CORNEAL THICKNESS; GOLDMANN APPLANATION TONOMETRY; OPEN-ANGLE GLAUCOMA; BIOMECHANICAL PROPERTIES; NONCONTACT TONOMETRY; DYNAMIC CONTOUR; EYES; REPRODUCIBILITY; CURVATURE;
D O I
10.1371/journal.pone.0170206
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of the study was to investigate the accuracy of two corrected intraocular pressure (IOP) measurements by Corvis Scheimpflug Technology (CST)-IOPpachy and by corneal compensated lOP (IOPcc) using the Reichert 7CR (7CR) tonometers. We also investigated the effects of corneal anatomical and structural parameters on the lOP measurements. The participants included 90 primary open-angle glaucoma patients. We assessed the lOP measurements, obtained by the CST, 7CR, and Goldmann applanation tonometer (GAT), using a paired t-test with Bonferroni correction, Bland-Altman plots, and multiple regression analyses. The 7CR-IOPcc gave the highest value (15.5 +/- 2.7 mmHg), followed by the 7CR-IOPg (13.7 3.1 mmHg), GAT-IOP (13.6 +/- 2.2 mmHg), CST-IOP (10.3 +/- 2.6 mmHg), and CST-IOPpachy (9.7 +/- 2.5 mmHg). The values of CST-IOPpachy were significantly lower than those obtained by the other lOP measurement methods (all, p < 0.01). The values of 7CR-IOPcc were significantly higher than those obtained by the other lOP measurement methods (all, p < 0.01). Bland-Altman plots showed a mean difference between the GAT-IOP and the other lOP measurements (CST-IOP, CST-IOPpachy, 7CR-IOPg, and 7CR-IOPcc), which were -3.20, -3.82, 0.14, and 2.00 mmHg, respectively. The widths of the 95% limits of agreement between all pairs of IOP measurements were greater than 3 mmHg. With the exception of the 7CR-IOPcc, all of the lOP variations were explained by regression coefficients involving gender, average corneal curvature, and central corneal thickness. The lOP values obtained by the GAT, CST, and 7CR were not interchangeable. Each new IOP measurement device that was corrected for ocular structure had its own limitations.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma
    Nakao, Yoshitaka
    Mohan, Rajiv R.
    Kiuchi, Yoshiaki
    Okumichi, Hideaki
    PLOS ONE, 2020, 15 (09):
  • [2] Comparison of Biomechanically Corrected Intraocular Pressure Obtained by Corvis ST and Goldmann Applanation Tonometry in Patients With Open-angle Glaucoma and Ocular Hypertension
    Ye, Yiming
    Yang, Yangfan
    Fan, Yanmei
    Lan, Min
    Yu, Keming
    Yu, Minbin
    JOURNAL OF GLAUCOMA, 2019, 28 (10) : 922 - 928
  • [3] Comparison of Intraocular Pressures Measured by the Corvis ST and Other Tonometers in Normal Eyes
    Lee, Seung-hoon
    Moon, Jung-il
    Jung, Youn Hea
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (12): : 1250 - 1256
  • [4] Comparison of intraocular pressure obtained by Goldmann applanation tonometer, Corvis ST and an airpuff tonometer in healthy adults
    Karmiris, Efthymios
    Tsiripidis, Konstantinos
    Gartaganis, Panos S.
    Totou, Styliani
    Vasilopoulou, Maria-Giannoula
    Patelis, Andreas
    Giannakis, Ioannis
    Chalkiadaki, Evangelia
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 951 - 959
  • [5] Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
    Gungor, Sirel G.
    Akman, Ahmet
    Yazici, Ayse C.
    JOURNAL OF GLAUCOMA, 2015, 24 (06) : 438 - 441
  • [6] Agreement of Corrected Intraocular Pressure Values Between Corvis ST and Pentacam in Patients With Keratoconus, Subclinical Keratoconus, and Normal Cornea
    Chen, Yanhui
    Rong, Hua
    Liu, Wei
    Liu, Guihua
    Du, Bei
    Jin, Chengcheng
    Wei, Ruihua
    CORNEA, 2021, 40 (11) : 1426 - 1432
  • [7] Comparison of Intraocular Pressure Measurements With the Reichert Pt100, the Keeler Pulsair Intellipuff Portable Noncontact Tonometers, and Goldmann Applanation Tonometry
    Hubanova, Ralitsa
    Aptel, Florent
    Zhou, Thierry
    Arnol, Nathalie
    Romanet, Jean-Paul
    Chiquet, Christophe
    JOURNAL OF GLAUCOMA, 2015, 24 (05) : 356 - 363
  • [8] Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST
    Eliasy, Ashkan
    Chen, Kai-Jung
    Vinciguerra, Riccardo
    Maklad, Osama
    Vinciguerra, Paolo
    Ambrosio Jr, Renato
    Roberts, Cynthia J.
    Elsheikh, Ahmed
    EXPERIMENTAL EYE RESEARCH, 2018, 175 : 98 - 102
  • [9] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Luebke, Jan
    Bryniok, L.
    Neuburger, M.
    Jordan, J. F.
    Boehringer, D.
    Reinhard, T.
    Wecker, T.
    Anton, A.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2517 - 2521
  • [10] Comparison of Intraocular Pressure Measurements Obtained Using Three Tonometers after Descemet Membrane Stripping Endothelial Keratoplasty
    Choi, Jeong Mun
    Kang, Yong Koo
    Kim, Hong Kyun
    Kim, Dai Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (07): : 605 - 612