Detection of cell-surface phosphatidylserine using the fluorogenic probe P-IID

被引:2
作者
Zwicker, Vincent E. [1 ]
Yeo, Jia Hao [1 ,2 ]
Fraser, Stuart T. [2 ]
New, Elizabeth J. [1 ]
Jolliffe, Katrina A. [1 ]
机构
[1] Univ Sydney, Sch Chem, Sydney, NSW, Australia
[2] Univ Sydney, Sch Med Sci, Camperdown, NSW, Australia
来源
CHEMICAL TOOLS FOR IMAGING, MANIPULATING, AND TRACKING BIOLOGICAL SYSTEMS: DIVERSE METHODS BASED ON OPTICAL IMAGING AND FLUORESCENCE | 2020年 / 640卷
基金
澳大利亚研究理事会;
关键词
APOPTOSIS; SENSOR; DEATH;
D O I
10.1016/bs.mie.2020.04.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fluorogenic probe P-IID enables the detection of cell-surface phosphatidylserine (PS) using both fluorescence imaging and flow cytometry. Here we provide a detailed protocol for the use of P-IID for the qualitative detection of externalized PS in apoptotic cells using confocal microscopy, including the real-time imaging of apoptosis upon drug treatment. We also provide a detailed method for the quantitative analysis of cell death by flow cytometry, using P-IID in conjunction with the nuclear stain propidium iodide. P-IID is superior to commonly used Annexin-V fluorophore conjugates for PS detection as it provides a "turn-on" fluorescence response, displays rapid binding kinetics and can be used at low temperature (4 degrees C), without washing and in the absence of Ca2+ ions.
引用
收藏
页码:291 / 307
页数:17
相关论文
共 16 条
  • [1] [Anonymous], 1972, J INTERN MED
  • [2] X-ray structure of a calcium-activated TMEM16 lipid scramblase
    Brunner, Janine D.
    Lim, Novandy K.
    Schenck, Stephan
    Duerst, Alessia
    Dutzler, Raimund
    [J]. NATURE, 2014, 516 (7530) : 207 - +
  • [3] Engeland M., 1996, Proc. Natl. Ac. Sci. USA, V93, P1, DOI DOI 10.1002/(SICI)1097-0320(19960601)24
  • [4] Jarvis TS, 2018, J MATER CHEM B, V6, P4963, DOI [10.1039/c8tb01495g, 10.1039/C8TB01495G]
  • [5] ANNEXIN-V FOR FLOW CYTOMETRIC DETECTION OF PHOSPHATIDYLSERINE EXPRESSION ON B-CELLS UNDERGOING APOPTOSIS
    KOOPMAN, G
    REUTELINGSPERGER, CPM
    KUIJTEN, GAM
    KEEHNEN, RMJ
    PALS, ST
    VANOERS, MHJ
    [J]. BLOOD, 1994, 84 (05) : 1415 - 1420
  • [6] Detection of apoptotic cells using a synthetic fluorescent sensor for membrane surfaces that contain phosphatidylserine
    Koulov, AV
    Stucker, KA
    Lakshmi, C
    Robinson, JP
    Smith, BD
    [J]. CELL DEATH AND DIFFERENTIATION, 2003, 10 (12) : 1357 - 1359
  • [7] Intramolecular Indicator Displacement Assay for Anions: Supramolecular Sensor for Glyphosate
    Minami, Tsuyoshi
    Liu, Yuanli
    Akdeniz, Ali
    Koutnik, Petr
    Esipenko, Nina A.
    Nishiyabu, Ryuhei
    Kubo, Yuji
    Anzenbacher, Pavel, Jr.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (32) : 11396 - 11401
  • [8] Programmed cell death pathways in cancer: a review of apoptosis, autophagy and programmed necrosis
    Ouyang, L.
    Shi, Z.
    Zhao, S.
    Wang, F. -T.
    Zhou, T. -T.
    Liu, B.
    Bao, J. -K.
    [J]. CELL PROLIFERATION, 2012, 45 (06) : 487 - 498
  • [9] What is apoptosis, and why is it important?
    Renehan, AG
    Booth, C
    Potten, CS
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7301): : 1536 - 1538
  • [10] Imaging and therapeutic applications of zinc(II)-dipicolylamine molecular probes for anionic biomembranes
    Rice, Douglas R.
    Clear, Kasey J.
    Smith, Bradley D.
    [J]. CHEMICAL COMMUNICATIONS, 2016, 52 (57) : 8787 - 8801