Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans

被引:55
作者
Sommer, Philipp [1 ]
Grothoff, Matthias [2 ]
Eitel, Charlotte [1 ]
Gaspar, Thomas [1 ]
Piorkowski, Christopher [1 ]
Gutberlet, Matthias [2 ]
Hindricks, Gerhard [1 ]
机构
[1] Univ Leipzig, Dept Electrophysiol, Ctr Heart, D-04289 Leipzig, Germany
[2] Univ Leipzig, Dept Diagnost & Intervent Radiol, Ctr Heart, Leipzig, Germany
来源
EUROPACE | 2013年 / 15卷 / 01期
关键词
Real-time MRI; EP study; Fluoroscopy; Radiation exposure; CATHETER ABLATION; ATRIAL; MRI;
D O I
10.1093/europace/eus230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) in the context of electrophysiology (EP) studies facilitates visualization of complex three-dimensional anatomy and the underlying arrhythmogenic substrate, real-time passive visualization of catheters, atrial and ventricular function and complications, as well as lesion visualization during the ablation without radiation. In the following we report on our first experience of a real-time MRI-guided EP study demonstrating current possibilities and drawbacks. Five consecutive patients (one male, four female; mean age 66 11 years) with symptomatic arrhythmias, three patients with highly symptomatic typical atrial flutter, presented to our hospital for isthmus ablation, one patient for an EP study and one for slow pathway ablation in atrioventricular node re-entry tachychardia. The four ablations were performed successfully in a conventional EP laboratory and complete bidirectional isthmus block was confirmed in three patients with atrial flutter. After the procedure in the EP laboratory all five patients were transferred to a 1.5 T whole-body MRI scanner (Intera) for a diagnostic EP procedure. Two MRI compatible steerable diagnostic/ablation catheters (Vision) were inserted via the femoral sheaths and manipulated by an experienced electrophysiologist using a commercially available interactive real-time steady-state free precession sequence (repetition time 3 ms, echo time 1 ms, flip angle 35, slice thickness 10 mm, frame rate 8/s). All catheters could be placed successfully in the right atrium and ventricle, confirmed by intracardiac electrograms, using passive catheter tracking. Furthermore, simple programmed stimulation maneuvers were performed. During and after the procedure, no adverse effects were observed in any patients. To our knowledge, this is the first series of patients with real-time MRI-guided placement of multiple catheters with subsequent performance of stimulation maneuvers. Besides the mentioned benefits, this technology still encounters several limitations, which have to be solved before application in a routine clinical setting. Challenges arise from delineation of precise surface electrocardiogram recordings in the MRI setting along with intracardiac electrograms, easier handling and visualization of catheters, facilitation of immediate defibrillation in the MRI setting and implementation of an active catheter tracking system.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 17 条
[1]  
Daccarett M, 2011, EXPERT REV CARDIOVAS, V9, P105, DOI [10.1586/erc.10.177, 10.1586/ERC.10.177]
[2]   Current practice of ventricular tachycardia ablation in patients with implantable cardioverter-defibrillators [J].
Dagres, Nikolaos ;
Cantu, Francesco ;
Geelen, Peter ;
Lewalter, Thorsten ;
Proclemer, Alessandro ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2012, 14 (01) :135-137
[3]   Electrophysiology study guided by real-time magnetic resonance imaging [J].
Eitel, Charlotte ;
Piorkowski, Christopher ;
Hindricks, Gerhard ;
Gutberlet, Matthias .
EUROPEAN HEART JOURNAL, 2012, 33 (15) :1975-1975
[4]   Color-coded three-dimensional entrainment mapping for analysis and treatment of atrial macroreentrant tachycardia [J].
Esato, Masahiro ;
Hindricks, Gerhard ;
Sommer, Philipp ;
Arya, Arash ;
Gaspar, Thomas ;
Bode, Kerstin ;
Bollmann, Andreas ;
Wetzel, Ulrike ;
Hilbert, Sebastian ;
Kircher, Simon ;
Eitel, Charlotte ;
Piorkowski, Christopher .
HEART RHYTHM, 2009, 6 (03) :349-358
[5]   Radiofrequency catheter ablation of common atrial flutter in 200 patients [J].
Fischer, B ;
Jais, P ;
Shah, DP ;
Chouairi, S ;
Haissaguerre, M ;
Garrigues, S ;
Poquet, F ;
Gencel, L ;
Clementy, J ;
Marcus, FI .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) :1225-1233
[6]  
Ganz LI, 1996, CORONARY ARTERY DIS, V7, P29
[7]   THE MULTICENTER-EUROPEAN-RADIOFREQUENCY-SURVEY (MERFS) - COMPLICATIONS OF RADIOFREQUENCY CATHETER ABLATION OF ARRHYTHMIAS [J].
HINDRICKS, G ;
ALIOT, E ;
ALMENDRAL, JM ;
AMLIE, J ;
ARLOTTI, M ;
BARNAY, C ;
BASHIR, Y ;
BERGFELDT, L ;
BLANC, J ;
HIMBERT, J ;
THOMSEN, PEB ;
BLOMSTROMLUNDQVIST, C ;
BREMBILLAPERROT, B ;
BRUGADA, P ;
BRUGADA, J ;
COWAN, JC ;
CAUCHEMEZ, B ;
CLEMENTY, J ;
COBBE, S ;
CRITELLI, G ;
CRIJNS, H ;
DAUBERT, JC ;
DESOUSA, J ;
DJIANE, P ;
DONZEAU, JP ;
DUCKECK, W ;
EDWARDSSON, N ;
FARRE, J ;
COSNAY, P ;
FONTAINE, G ;
FROMER, M ;
GOICOLEA, A ;
GONSKA, BD ;
GROLLEAURAOUX, R ;
HAISSAGUERRE, M ;
HAVERKAMP, W ;
HERMIDA, JS ;
HIEF, C ;
HOPP, HW ;
HOFFMAN, E ;
HUIKURI, H ;
JORDAENS, L ;
KALUSCHE, D ;
KUHLKAMP, V ;
LAUCEVICIUS, A ;
LAVERGNE, T ;
MANZ, M ;
MOLLER, M ;
MONT, L ;
NATHAN, AW .
EUROPEAN HEART JOURNAL, 1993, 14 (12) :1644-1653
[8]   Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model [J].
Hoffmann, Boris A. ;
Koops, Andreas ;
Rostock, Thomas ;
Muellerleile, Kai ;
Steven, Daniel ;
Karst, Roman ;
Steinke, Mark U. ;
Drewitz, Imke ;
Lund, Gunnar ;
Koops, Susan ;
Adam, Gerhard ;
Willems, Stephan .
EUROPEAN HEART JOURNAL, 2010, 31 (04) :450-456
[9]   Evaluation of the left atrial substrate in patients with lone atrial fibrillation using delayed-enhanced MRI: Implications for disease progression and response to catheter ablation [J].
Mahnkopf, Christian ;
Badger, Troy J. ;
Burgon, Nathan S. ;
Daccarett, Marcos ;
Haslam, Thomas S. ;
Badger, Christopher T. ;
McGann, Christopher J. ;
Akoum, Nazem ;
Kholmovski, Eugene ;
Macleod, Rob S. ;
Marrouche, Nassir F. .
HEART RHYTHM, 2010, 7 (10) :1475-1481
[10]   NASPE SURVEY ON CATHETER ABLATION [J].
MARKELL, RL ;
SCHEINMAN, MM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08) :1474-1478