Clinical significance of platelet-associated hematological parameters as an early supplementary diagnostic tool for sepsis in thrombocytopenic very-low-birth-weight infants

被引:7
作者
Kim, Ju Yeon [1 ]
Yoon, Jeongah [2 ]
Lim, Chae Seung [3 ]
Choi, Byung Min [4 ]
Yoon, Soo-Young [3 ]
机构
[1] Univ Korea Hosp, Dept Lab Med, Seoul, South Korea
[2] Korea Univ, Coll Med, Translat Res Inst Incurable Dis, Seoul 152703, South Korea
[3] Korea Univ, Coll Med, Dept Lab Med, Seoul 152703, South Korea
[4] Korea Univ, Coll Med, Dept Pediat, Seoul 152703, South Korea
基金
新加坡国家研究基金会;
关键词
Mean platelet volume; platelet count; platelet distribution width; sepsis; thrombocytopenia; very-low-birth-weight infants; INTENSIVE-CARE-UNIT; DISTRIBUTION WIDTH; BACTERIAL; MANAGEMENT; INFECTION; COAGULATION; SYSTEM; VOLUME; COUNT; SIZE;
D O I
10.3109/09537104.2014.963542
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Sepsis is an important cause of death in very-low-birth-weight (VLBW) neonates. Although conventional diagnostic indicator of sepsis has been done by blood cultures, this took much longer time. The measurement of platelet-associated parameters such as mean platelet volume (MPV) and platelet distribution width (PDW) become more reliable and accurate parameters as a non-specific marker for sepsis. Our objective is to examine the usefulness of those platelet hematological parameters as a supplementary diagnostic tool for sepsis in VLBW infants. This study is a retrospective cohort study of neonates subject to the diagnosis of sepsis from October 2006 to July 2010. This study was conducted at Korea University medical center. We studied total 2,336 infants for 32 days from birth (Day 0) to Day 31. We compared three groups of infants to examine differences of platelet parameters according to their age from birth to Day 31: (i) full-terms versus VLBW without sepsis, (ii) VLBW without sepsis versus VLBW with sepsis and (iii) thrombocytopenic VLBW without sepsis versus those with sepsis. The platelet-associated parameters were significantly distinguishable between septic and non-septic groups at their early age (similar to 1 week), especially platelet counts (PLT) (p = 0.0091), MPV (p = 0.007) and PDW (p = 0.0372) in thrombocytopenic VLBW infants. The decreased PLT, elevated MPV and PDW were major characteristics of septic group. We suggested maximum cutoff values of the platelet factors by performing receiver operating characteristic curve analysis between septic and non-septic thrombocytopenic VLBW infants, among which MPV was the most promising index (AUC(MPV) = 0.7044>AUC(PLT) = 0.6921>AUC(PDW) = 0.6593). Platelet-associated hematological parameters are useful for the early diagnosis of sepsis as a more efficient and supplementary diagnostic method in thrombocytopenic VLBW infants.
引用
收藏
页码:620 / 626
页数:7
相关论文
共 42 条
  • [11] Dellinger P, 2001, CRIT CARE MED, V29, pS67
  • [12] Definition of reference ranges for the platelet distribution width (PDW): a local need
    Farias, Mariela Granero
    Schunck, Elias Guilherme
    Dal Bo, Suzane
    de Castro, Simone Martins
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (02) : 255 - 257
  • [13] Coagulation in severe sepsis: A central role for thrombomodulin and activated protein C
    Faust, SN
    Heyderman, RS
    Levin, M
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (07) : S62 - S67
  • [14] Gaynes RP, 1996, PEDIATRICS, V98, P357
  • [15] Diagnosis and management of bacterial infections in the neonate
    Gerdes, JS
    [J]. PEDIATRIC CLINICS OF NORTH AMERICA, 2004, 51 (04) : 939 - +
  • [16] Effect of severe sepsis on platelet count and their indices
    Guclu, E.
    Durmaz, Y.
    Karabay, O.
    [J]. AFRICAN HEALTH SCIENCES, 2013, 13 (02) : 333 - 338
  • [17] Platelet count and sepsis in very low birth weight neonates: Is there an organism-specific response?
    Guida, JD
    Kunig, AM
    Leef, KH
    McKenzie, SE
    Paul, DA
    [J]. PEDIATRICS, 2003, 111 (06) : 1411 - 1415
  • [18] Haque K N., 2010, Journal of medical sciences, V3, P1
  • [19] Platelet size deviation width, platelet large cell ratio, and mean platelet volume have sufficient sensitivity and specificity in the diagnosis of immune thrombocytopenia
    Kaito, K
    Otsubo, H
    Usui, N
    Yoshida, M
    Tanno, J
    Kurihara, E
    Matsumoto, K
    Hirata, R
    Domitsu, K
    Kobayashi, M
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2005, 128 (05) : 698 - 702
  • [20] Clinical microbiology of bacterial and fungal sepsis in very-low-birth-weight infants
    Kaufman, D
    Fairchild, KD
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 2004, 17 (03) : 638 - +