Energetic optimization of regenerative Organic Rankine Cycle (ORC) configurations

被引:144
作者
Braimakis, Konstantinos [1 ]
Karellas, Sotirios [1 ]
机构
[1] Natl Tech Univ Athens, Lab Steam Boilers & Thermal Plants, 9 Heroon Polytech, Zografos 15780, Greece
关键词
ORC; Regenerative; Recuperator; Optimization; Bleed; Double stage; WASTE HEAT-RECOVERY; GEOTHERMAL POWER-PLANTS; LIQUEFIED NATURAL-GAS; THERMOECONOMIC OPTIMIZATION; WORKING FLUIDS; EXERGOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; PERFORMANCE ANALYSIS; SYSTEM; TEMPERATURE;
D O I
10.1016/j.enconman.2017.12.093
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study focuses on the energetic optimization of regenerative Organic Rankine Cycle (ORC) configurations. More specifically, three regenerative ORCs are examined. The first includes an open preheater, in which the bleed stream is mixed with the working fluid exiting the pump of the cycle (O-ORC). The other two configurations include a closed preheater. In the second configuration, the bleed stream is throttled and conveyed to the condenser (CB-ORC), while in the third one, it is repressurized via a secondary pump and re circulates into the evaporator of the cycle (CF-ORC). The systems are optimized for different working fluids, and their energetic efficiencies are estimated and compared to that of a standard ORC (S-ORC). In all cases, the inclusion of a recuperator has also been investigated. In principle, recuperative and regenerative ORCs are mostly suitable for dry fluids, while the critical temperature can also have a positive influence on the performance improvement. Furthermore, it is estimated that while the recuperative S-ORC has a higher efficiency than the non-recuperative regenerative cycles, recuperative O-ORC and CF-ORC exhibit a relative efficiency gain ranging from 4.98% to 8.05% and 6.22% to 9.29%, respectively. The highest efficiency improvement achieved by the CB-ORC, however, is minimal.
引用
收藏
页码:353 / 370
页数:18
相关论文
共 44 条
[41]   Exergetic analysis of various types of geothermal power plants [J].
Yari, Mortaza .
RENEWABLE ENERGY, 2010, 35 (01) :112-121
[42]   A comparative exergoeconomic analysis of different ORC configurations for binary geothermal power plants [J].
Zare, V. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :127-138
[43]   Comparative study of alternative ORC-based combined power systems to exploit high temperature waste heat [J].
Zhang, Chengyu ;
Shu, Gequn ;
Tian, Hua ;
Wei, Haiqiao ;
Liang, Xingyu .
ENERGY CONVERSION AND MANAGEMENT, 2015, 89 :541-554
[44]   A performance analysis of a novel system of a dual loop bottoming organic Rankine cycle (ORC) with a light-duty diesel engine [J].
Zhang, H. G. ;
Wang, E. H. ;
Fan, B. Y. .
APPLIED ENERGY, 2013, 102 :1504-1513