Energetic optimization of regenerative Organic Rankine Cycle (ORC) configurations

被引:146
作者
Braimakis, Konstantinos [1 ]
Karellas, Sotirios [1 ]
机构
[1] Natl Tech Univ Athens, Lab Steam Boilers & Thermal Plants, 9 Heroon Polytech, Zografos 15780, Greece
关键词
ORC; Regenerative; Recuperator; Optimization; Bleed; Double stage; WASTE HEAT-RECOVERY; GEOTHERMAL POWER-PLANTS; LIQUEFIED NATURAL-GAS; THERMOECONOMIC OPTIMIZATION; WORKING FLUIDS; EXERGOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; PERFORMANCE ANALYSIS; SYSTEM; TEMPERATURE;
D O I
10.1016/j.enconman.2017.12.093
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study focuses on the energetic optimization of regenerative Organic Rankine Cycle (ORC) configurations. More specifically, three regenerative ORCs are examined. The first includes an open preheater, in which the bleed stream is mixed with the working fluid exiting the pump of the cycle (O-ORC). The other two configurations include a closed preheater. In the second configuration, the bleed stream is throttled and conveyed to the condenser (CB-ORC), while in the third one, it is repressurized via a secondary pump and re circulates into the evaporator of the cycle (CF-ORC). The systems are optimized for different working fluids, and their energetic efficiencies are estimated and compared to that of a standard ORC (S-ORC). In all cases, the inclusion of a recuperator has also been investigated. In principle, recuperative and regenerative ORCs are mostly suitable for dry fluids, while the critical temperature can also have a positive influence on the performance improvement. Furthermore, it is estimated that while the recuperative S-ORC has a higher efficiency than the non-recuperative regenerative cycles, recuperative O-ORC and CF-ORC exhibit a relative efficiency gain ranging from 4.98% to 8.05% and 6.22% to 9.29%, respectively. The highest efficiency improvement achieved by the CB-ORC, however, is minimal.
引用
收藏
页码:353 / 370
页数:18
相关论文
共 44 条
[1]   Effect of dry hydrocarbons and critical point temperature on the efficiencies of organic Rankine cycle [J].
Aljundi, Isam H. .
RENEWABLE ENERGY, 2011, 36 (04) :1196-1202
[2]  
American Society of Heating Refrigeration and Air-Conditioning Engineers, 2013, DES SAF CLASS REFR
[3]   Binary ORC (Organic Rankine Cycles) power plants for the exploitation of medium low temperature geothermal sources - Part B: Techno-economic optimization [J].
Astolfi, Marco ;
Romano, Matteo C. ;
Bombarda, Paola ;
Macchi, Ennio .
ENERGY, 2014, 66 :435-446
[4]   ORC optimization for medium grade heat recovery [J].
Ayachi, Fadhel ;
Ksayer, Elias Boulawz ;
Zoughaib, Assaad ;
Neveu, Pierre .
ENERGY, 2014, 68 :47-56
[5]   A review of working fluid and expander selections for organic Rankine cycle [J].
Bao, Junjiang ;
Zhao, Li .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 24 :325-342
[6]   Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp [J].
Bell, Ian H. ;
Wronski, Jorrit ;
Quoilin, Sylvain ;
Lemort, Vincent .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (06) :2498-2508
[7]   Thermo-economic evaluation of various bottoming ORCs for geothermal power plant, determination of optimum cycle for Sabalan power plant exhaust [J].
Bina, Saeid Mohammadzadeh ;
Jalilinasrabady, Saeid ;
Fujii, Hikari .
GEOTHERMICS, 2017, 70 :181-191
[8]  
Braimakis K, 2015, ENERGY EXERGY ANAL E
[9]   Technoeconomic Analysis and Comparison of a Solar-Based Biomass ORC-VCC System and a PV Heat Pump for Domestic Trigeneration [J].
Braimakis, Konstantinos ;
Thimo, Antzela ;
Karellas, Sotirios .
JOURNAL OF ENERGY ENGINEERING, 2017, 143 (02)
[10]   Integrated thermoeconomic optimization of standard and regenerative ORC for different heat source types and capacities [J].
Braimakis, Konstantinos ;
Karellas, Sotirios .
ENERGY, 2017, 121 :570-598