Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-Month and 12-month serial follow-up

被引:32
作者
Kim, Byeong-Keuk [1 ]
Hong, Myeong-Ki [1 ,2 ]
Shin, Dong-Ho [1 ]
Kim, Jung-Sun [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
Optical coherence tomography; Drug-eluting stent; Coronary artery disease; CORONARY-ARTERY-DISEASE; BIODEGRADABLE POLYMER; DURABLE POLYMER; THROMBOSIS; LEADERS;
D O I
10.1016/j.ijcard.2013.07.160
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES). Methods: A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n = 30) and SES (n = 30) implantation groups. Serial OCT evaluation at post-procedure, 3-and 12-month follow-up was performed in 46 patients [BES (n = 22) and SES (n = 24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Delta) of uncovered struts in the 3-and 12-month follow-up samples. Results: The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p = 0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p = 0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage. of uncovered struts from 3-12 months than that of SES [-17.2 +/- 14.5% versus -7.7 +/- 16.3%, respectively (p = 0.043)]. Conclusions: Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:4617 / 4623
页数:7
相关论文
共 24 条
[21]   The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography [J].
Tanigawa, Jun ;
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Dalby, Miles ;
Moore, Philip ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (02) :180-188
[22]   Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography Studies A Report From the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation [J].
Tearney, Guillermo J. ;
Regar, Evelyn ;
Akasaka, Takashi ;
Adriaenssens, Tom ;
Barlis, Peter ;
Bezerra, Hiram G. ;
Bouma, Brett ;
Bruining, Nico ;
Cho, Jin-man ;
Chowdhary, Saqib ;
Costa, Marco A. ;
de Silva, Ranil ;
Dijkstra, Jouke ;
Di Mario, Carlo ;
Dudeck, Darius ;
Falk, Erlin ;
Feldman, Marc D. ;
Fitzgerald, Peter ;
Garcia, Hector ;
Gonzalo, Nieves ;
Granada, Juan F. ;
Guagliumi, Giulio ;
Holm, Niels R. ;
Honda, Yasuhiro ;
Ikeno, Fumiaki ;
Kawasaki, Masanori ;
Kochman, Janusz ;
Koltowski, Lukasz ;
Kubo, Takashi ;
Kume, Teruyoshi ;
Kyono, Hiroyuki ;
Lam, Cheung Chi Simon ;
Lamouche, Guy ;
Lee, David P. ;
Leon, Martin B. ;
Maehara, Akiko ;
Manfrini, Olivia ;
Mintz, Gary S. ;
Mizuno, Kyiouchi ;
Morel, Marie-angele ;
Nadkarni, Seemantini ;
Okura, Hiroyuki ;
Otake, Hiromasa ;
Pietrasik, Arkadiusz ;
Prati, Francesco ;
Raeber, Lorenz ;
Radu, Maria D. ;
Rieber, Johannes ;
Riga, Maria ;
Rollins, Andrew .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (12) :1058-1072
[23]   Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious? [J].
Virmani, R ;
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Grieco, N ;
Motta, T ;
Mihalcsik, L ;
Tespili, M ;
Valsecchi, O ;
Kolodgie, FD .
CIRCULATION, 2004, 109 (06) :701-705
[24]   Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS):: a randomised non-inferiority trial [J].
Windecker, Stephan ;
Serruys, Patrick W. ;
Wandel, Simon ;
Buszman, Pawel ;
Trznadel, Stanislaw ;
Linke, Axel ;
Lenk, Karsten ;
Ischinger, Thomas ;
Klauss, Volker ;
Eberli, Franz ;
Corti, Roberto ;
Wijns, William ;
Morice, Marie Claude ;
di Mario, Carlo ;
Davies, Simon ;
van Geuns, Robert-Jan ;
Eerdmans, Pedro ;
van Es, Gerrit-Anne ;
Meier, Bernhard ;
Jueni, Peter .
LANCET, 2008, 372 (9644) :1163-1173