Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback

被引:40
作者
Chopra, R
Wachsmuth, J
Burtnyk, M
Haider, MA
Bronskill, MJ
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Princess Margaret Hosp, Hlth Network, Dept Med Imaging, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1088/0031-9155/51/4/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The feasibility of using MR thermometry for temperature feedback to control a transurethral ultrasound heating applicator with planar transducers was investigated. The sensitivity of a temperature-based feedback algorithm to spatial (control point area, slice thickness, angular alignment) and non-spatial (imaging time, temperature uncertainty) parameters was evaluated through numerical simulations. The angular alignment of the control point with the ultrasound beam was an important parameter affecting the average spatial error in beat delivery. The other spatial parameters were less influential, thus providing an opportunity to reduce spatial resolution for increased SNR in the MR imaging. The update time was the most important non-spatial parameter determining the performance of the control algorithm. Combined non-spatial and spatial parameters achieved acceptable performance with it voxel size of 3 mm x 3 mm, it 10 mm slice thickness and a 5 s update time. Temperature uncertainty of up to 2 degrees C had little effect on the performance of the control algorithm but did reduce the average error slightly Clue to a systematic, noise-induced overestimation of the boundary temperature. These simulations imply that MR thermometry performed on clinical 1.5 T imaging systems is of sufficient quality for use as thermal feedback for conformal prostate thermal therapy with transurethral ultrasound heating applicators incorporating planar transducers.
引用
收藏
页码:827 / 844
页数:18
相关论文
共 49 条
  • [1] [Anonymous], 2004, CAN CANC STAT 2004
  • [2] Model-predictive control of hyperthermia treatments
    Arora, D
    Skliar, M
    Roemer, RB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 629 - 639
  • [3] BEHNIA B, 2002, MAGN RESON ENG, V15, P101
  • [4] TIME-TEMPERATURE ANALYSIS OF CELL KILLING OF BHK CELLS HEATED AT TEMPERATURES IN THE RANGE OF 43.5-DEGREES-C TO 57.0-DEGREES-C
    BORRELLI, MJ
    THOMPSON, LL
    CAIN, CA
    DEWEY, WC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (02): : 389 - 399
  • [5] Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience
    Chen, JC
    Moriarty, JA
    Derbyshire, JA
    Peters, RD
    Trachtenberg, J
    Bell, SD
    Doyle, J
    Arrelano, R
    Wright, GA
    Henkelman, RM
    Hinks, RS
    Lok, SY
    Toi, A
    Kucharczyk, W
    [J]. RADIOLOGY, 2000, 214 (01) : 290 - 297
  • [6] Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators
    Chopra, R
    Burtnyk, M
    Haider, MA
    Bronskill, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) : 4957 - 4975
  • [7] Multifrequency ultrasound transducers for conformal interstitial thermal therapy
    Chopra, R
    Luginbuhl, C
    Foster, FS
    Bronskill, MJ
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (07) : 881 - 889
  • [8] Interstitial ultrasound heating applicator for MR-guided thermal therapy
    Chopra, R
    Luginbuhl, C
    Weymouth, AJ
    Foster, FS
    Bronskill, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) : 3133 - 3145
  • [9] Feasibility of linear arrays for interstitial ultrasound thermal therapy
    Chopra, R
    Bronskill, MJ
    Foster, FS
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1281 - 1286
  • [10] Evaluation of a fuzzy logic controller for laser thermal therapy
    Choy, VWS
    Sadeghian, A
    Sherar, MD
    Whelan, WM
    [J]. LASER TISSUE INTERACTION XIII: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, 2002, 4617 : 77 - 86