共 50 条
Identification of intraplaque haemorrhage in carotid artery by simultaneous non-contrast angiography and intraPlaque haemorrhage (SNAP) imaging: a magnetic resonance vessel wall imaging study
被引:32
|作者:
Li, Dongye
[1
,2
]
Zhao, Huilin
[3
]
Chen, Xiaoyi
[1
,2
,4
]
Chen, Shuo
[4
]
Qiao, Huiyu
[4
]
He, Le
[4
]
Li, Rui
[4
]
Xu, Jianrong
[3
]
Yuan, Chun
[4
,6
]
Zhao, Xihai
[4
,5
]
机构:
[1] Capital Med Univ, Ctr Brain Disorders Res, Beijing, Peoples R China
[2] Beijing Inst Brain Disorders, Beijing, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Renji Hosp, Dept Radiol, Shanghai, Peoples R China
[4] Tsinghua Univ, Dept Biomed Engn, Ctr Biomed Imaging Res, Sch Med, Beijing 100084, Peoples R China
[5] Beijing Inst Brain Disorders, Ctr Stroke, Beijing, Peoples R China
[6] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金:
中国国家自然科学基金;
关键词:
Carotid artery;
Atherosclerosis;
Intraplaque haemorrhage (IPH);
Magnetic resonance imaging;
SNAP;
NONCONTRAST ANGIOGRAPHY;
EVENTS;
PLAQUES;
DISEASE;
MRI;
3T;
D O I:
10.1007/s00330-017-5096-1
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
To investigate the usefulness of Simultaneous Non-contrast Angiography and intraPlaque haemorrhage (SNAP) imaging in characterising carotid intraplaque haemorrhage (IPH) compared with magnetisation-prepared rapid acquisition gradient-echo (MP-RAGE) sequence. Fifty-four symptomatic patients (mean age: 63.1 +/- 5.7 years, 38 males) with carotid atherosclerosis were recruited and underwent carotid MR imaging. The presence and area of IPH on SNAP and MP-RAGE images were determined. The agreement in identifying IPH and its area between SNAP and MP-RAGE was analysed. Of 1368 slices with acceptable image quality in 54 patients, 13% and 22.6% were found to have IPH on MP-RAGE and SNAP images, respectively. There was moderate agreement between MP-RAGE and SNAP sequences in identifying IPH (kappa = 0.511, p = 0.029). The area of IPH on SNAP images was significantly larger than that on MP-RAGE images (17.9 +/- 18.2 mm(2) vs. 9.2 +/- 10.5 mm(2), p < 0.001). For IPHs detected by SNAP imaging, the area of IPHs also detected by the MP-RAGE sequence was significantly larger than that of IPHs not detected by the MP-RAGE sequence (17.9 +/- 19.2 mm(2) vs. 6.4 +/- 6.2 mm(2), p < 0.001). Compared with the MP-RAGE sequence, SNAP imaging detects more IPHs, particularly for smaller IPHs, suggesting that SNAP imaging might be a more sensitive tool for identification of carotid haemorrhagic plaques. aEuro cent Moderate agreement was found between SNAP and MP-RAGE in identification of IPH aEuro cent SNAP imaging might be a more sensitive tool to detect carotid IPHs aEuro cent Compared with the MP-RAGE sequence, SNAP imaging can detect carotid IPHs with smaller size aEuro cent SNAP imaging can help clinicians to optimise the treatment strategy.
引用
收藏
页码:1681 / 1686
页数:6
相关论文