Maternal and umbilical cord ischemia-modified albumin levels in nonreassuring fetal heart rate tracings regarding the mode of delivery

被引:8
作者
Caglar, Gamze S. [1 ]
Tasci, Yasemin [2 ]
Goktolga, Umit [2 ]
Oztas, Efser [1 ]
Pabuccu, Recai [1 ]
Ozdemir, Elif D. [1 ]
Seker, Rabia [3 ]
机构
[1] Ufuk Univ, Sch Med, Dept Obstet & Gynecol, Ankara, Turkey
[2] Etlik Zubeyde Hanim Womens Hlth Res Hosp, Dept Obstet & Gynecol, Minist Hlth, TR-06010 Ankara, Turkey
[3] Ufuk Univ, Sch Med, Dept Biochem, Ankara, Turkey
关键词
Ischemia-modified albumin; fetal distress; elective repeat cesarean section; COBALT-BINDING; BLOOD;
D O I
10.3109/14767058.2012.743519
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate umbilical cord blood ischemia-modified albumin (IMA) levels in cases of fetal distress (FD) and to explore fetal blood IMA levels regarding the route of delivery. Methods: Umbilical cord and maternal serum IMA concentrations were assessed in term 40 cases with cesarean section (CS) due to FD, 76 cases with elective repeat CS and 85 cases with noncomplicated vaginal delivery. Results: The maternal and umbilical cord IMA levels were significantly lower in vaginal deliveries when compared with CS cases either in FD or previous CS groups (p = 0.02). Although no statistically significant difference was found in IMA levels of CS groups (previous CS vs. FD), cord blood IMA levels tend to be higher in FD group. Neither demographic characteristics nor fetal outcome parameters were found to have any correlation with maternal IMA levels. However, umbilical cord IMA levels were found to be negatively correlated with 1th min Apgar scores (r = -0.143, p = 0.043). Conclusions: IMA seems to be responsive to hypoxic FD showing the highest levels in cases with severe fetal hypoxia. Higher levels of IMA in cases with elective repeat CS might indicate acute transient hypoxia and possible myocardial ischemia in these cases.
引用
收藏
页码:528 / 531
页数:4
相关论文
共 15 条
  • [1] Apple FS, 2002, CLIN CHEM, V48, P1097
  • [2] Oxidative stress in the fetal circulation does not depend on mode of delivery
    Fogel, I
    Pinchuk, I
    Kupferminc, MJ
    Lichtenberg, D
    Fainaru, O
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 193 (01) : 241 - 246
  • [3] Problems with intrapartum fetal heart rate monitoring interpretation and patient management
    Freeman, RK
    [J]. OBSTETRICS AND GYNECOLOGY, 2002, 100 (04) : 813 - 826
  • [4] Ischemia Modified Albumin: A Novel Biomarker for the Detection of Cardiac Ischemia
    Gaze, David C.
    [J]. DRUG METABOLISM AND PHARMACOKINETICS, 2009, 24 (04) : 333 - 341
  • [5] Ischemia-modified albumin levels in cord blood: A case-control study in uncomplicated and complicated deliveries
    Gugliucci, A
    Herrno, R
    Monroy, C
    Numaguchi, M
    Kimura, S
    [J]. CLINICA CHIMICA ACTA, 2005, 362 (1-2) : 155 - 160
  • [6] Cord blood ischemia-modified albumin levels in normal and intrauterine growth restricted pregnancies
    Iacovidou, Nicoletta
    Briana, Despina D.
    Boutsikou, Maria
    Liosi, Sophia
    Baka, Stavroula
    Boutsikou, Theodora
    Hassiakos, Demetrios
    Malamitsi-Puchner, Ariadne
    [J]. MEDIATORS OF INFLAMMATION, 2008, 2008
  • [7] Predictive value of fetal scalp blood lactate concentration and pH as markers of neurologic disability
    Kruger, K
    Hallberg, B
    Blennow, M
    Kublickas, M
    Westgren, M
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1999, 181 (05) : 1072 - 1078
  • [8] Albumin cobalt binding and ischemia modified albumin generation: An endogenous response to ischemia?
    Lippi, G
    Montagnana, M
    Guldi, GC
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 108 (03) : 410 - 411
  • [9] The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring - Update on definitions, interpretation, and research guidelines
    Macones, George A.
    Hankins, Gary D. V.
    Spong, Catherine Y.
    Hauth, John
    Moore, Thomas
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 112 (03) : 661 - 666
  • [10] Uncertain value of electronic fetal monitoring in predicting cerebral palsy
    Nelson, KB
    Dambrosia, JM
    Ting, TY
    Grether, JK
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (10) : 613 - 618