Lung tissue concentrations of nebulized amikacin during mechanical ventilation in piglets with healthy lungs

被引:82
|
作者
Goldstein, I
Wallet, F
Robert, J
Becquemin, MH
Marquette, CH
Rouby, JJ
机构
[1] Univ Paris 06, Hop La Pitie Salpetriere, Dept Anesthesiol, Pierre Viars Surg Intens Care Unit, F-75013 Paris, France
[2] Univ Paris 06, Hop La Pitie Salpetriere, Dept Bacteriol, F-75013 Paris, France
[3] Univ Paris 06, Hop La Pitie Salpetriere, Serv Explorat Fonctionnelles Resp, F-75013 Paris, France
[4] Univ Paris 06, Hop La Pitie Salpetriere, UPRES 2397, F-75013 Paris, France
[5] Univ Med Lille, DHURE, Dept Bacteriol, Lille, France
[6] Univ Med Lille, INSERM, U 416, Lille, France
关键词
aerosol; amikacin; piglets; mechanical ventilation;
D O I
10.1164/ajrccm.165.2.2107025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The tissue concentration of aminoglycosides in lung parenchyma is the main determinant of bactericidal efficiency. The aim of the study was to compare the lung deposition of amikacin administered either by an ultrasonic nebulizer or by intravenous infusion during mechanical ventilation. Eighteen healthy ventilated piglets received a single daily dose of amikacin by intravenous infusion (15 mg . kg(-1)) and 18 by aerosol (1 g in 12 ml). The amount of aerosolized amikacin reaching the tracheobronchial tree represented 40 +/- 5% of the initial dose with an aerodynamic size distribution showing 50% of particles ranging between 0.5 and 5 mum mass median diameter. Animals were killed at different time intervals after the second dose. Tissue concentrations of amikacin were determined on cryomixed multiple lung specimen by an immunoenzymatic method. The lung concentrations of nebulized amikacin, peaking at 208 +/- 76 mug . g(-1), were more than 10-fold higher than the lung concentrations of intravenous amikacin and were homogeneously distributed throughout the lung parenchyma. Amikacin plasma concentrations lower than 5 mmol . l(-1) were measured after the sixth hour after the nebulization. In conclusion, the ultrasonic nebulization of amikacin resulted in high tissue concentrations, far above the minimal inhibitory concentrations of most gram-negative strains.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 50 条
  • [21] Modern methods of assessment of lung aeration during mechanical ventilation
    Wierzejski, Wojciech
    Adamski, Jan
    Weigl, Wojciech
    Gerega, Anna
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2012, 44 (04) : 226 - 231
  • [22] Fluctuations of inspired concentrations of nitric oxide and nitrogen dioxide during mechanical ventilation
    Ralf Kuhlen
    Thilo Busch
    Martin Max
    Matthias Reyle-Hahn
    Konrad J Falke
    Rolf Rossaint
    Critical Care, 3
  • [23] Effects of dexmedetomidine on oxidative stress and inflammatory response in lungs during mechanical ventilation in COPD rats
    Li, Pengcheng
    Han, Jing
    Zhang, Dan
    Cao, Shu
    Su, Chunyu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (02) : 1219 - 1224
  • [24] The individual does not feel an air hunger during the control apparatus of mechanical ventilation of his lungs
    Pogodin, Michail
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [25] Administration of Bacteriophages via Nebulization during Mechanical Ventilation: In Vitro Study and Lung Deposition in Macaques
    Le Guellec, Sandrine
    Pardessus, Jeoffrey
    Bodier-Montagutelli, Elsa
    L'Hostis, Guillaume
    Dalloneau, Emilie
    Piel, Damien
    Samai, Hakim Chouky
    Guillon, Antoine
    Mujic, Elvir
    Guillot-Combe, Emmanuelle
    Ehrmann, Stephan
    Morello, Eric
    Gabard, Jerome
    Heuze-Vourc'h, Nathalie
    Fevre, Cindy
    Vecellio, Laurent
    VIRUSES-BASEL, 2023, 15 (03):
  • [26] Fluctuations of inspired concentrations of nitric oxide and nitrogen dioxide during mechanical ventilation
    Kuhlen, R
    Busch, T
    Max, M
    Reyle-Hahn, M
    Falke, KJ
    Rossaint, R
    CRITICAL CARE, 1999, 3 (01): : 1 - 6
  • [27] AEROSOL DELIVERY DURING MECHANICAL VENTILATION - A PREDICTIVE INVITRO LUNG MODEL
    FULLER, HD
    DOLOVICH, MB
    CHAMBERS, C
    NEWHOUSE, MT
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1992, 5 (04): : 251 - 259
  • [28] Right Ventricular Loading by Lung Inflation during Controlled Mechanical Ventilation
    Slobod, Douglas
    Assanangkornchai, Nawaporn
    Alhazza, Manal
    Mettasittigorn, Pattra
    Magder, Sheldon
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205 (11) : 1311 - 1319
  • [29] Pulmonary surfactant is altered during mechanical ventilation of isolated rat lung
    Veldhuizen, RAW
    Tremblay, LN
    Govindarajan, A
    van Rozendaal, BAWM
    Haagsman, HP
    Slutsky, AS
    CRITICAL CARE MEDICINE, 2000, 28 (07) : 2545 - 2551
  • [30] Lung sound analysis to detect recruitment processes during mechanical ventilation
    K Möller
    Y Lu
    B Vondenbusch
    S Schließmann
    S Schumann
    A Kirschbaum
    J Guttmann
    Critical Care, 12 (Suppl 2):