Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

被引:39
作者
Clauser, Paola [1 ]
Nagl, Georg [2 ]
Helbich, Thomas H. [1 ]
Pinker-Domenig, Katja [1 ]
Weber, Michael [3 ]
Kapetas, Panagiotis [1 ]
Bernathova, Maria [1 ]
Baltzer, Pascal A. T. [1 ]
机构
[1] Med Univ Vienna, Div Mol & Gender Imaging, Dept Biomed Imaging & Image Guided Therapy, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Landesklinikum Horn, Dept Radiol & Intervent Radiol, Spitalgasse 10, A-3580 Horn, Austria
[3] Med Univ Vienna, Div Gen & Pediat Radiol, Dept Biomed Imaging & Image Guided Therapy, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
Breast cancer; Mammography; Microcalcifications; Digital breast tomosynthesis; Comparative studies; DOSIMETRIC CHARACTERIZATION; OBSERVER; CALCIFICATIONS; VARIABILITY; ACQUISITION; EXPERIENCE; CLUSTERS; LESIONS; SYSTEM; 2-VIEW;
D O I
10.1016/j.ejrad.2016.10.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients' history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions' characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2161 / 2168
页数:8
相关论文
共 33 条
[21]   A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications [J].
Sechopoulos, Ioannis .
MEDICAL PHYSICS, 2013, 40 (01)
[22]   Optimization of the acquisition geometry in digital tomosynthesis of the breast [J].
Sechopoulos, Ioannis ;
Ghetti, Caterina .
MEDICAL PHYSICS, 2009, 36 (04) :1199-1207
[23]   Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images [J].
Skaane, Per ;
Bandos, Andriy I. ;
Eben, Ellen B. ;
Jebsen, Ingvild N. ;
Krager, Mona ;
Haakenaasen, Unni ;
Ekseth, Ulrika ;
Izadi, Mina ;
Hofvind, Solveig ;
Gullien, Randi .
RADIOLOGY, 2014, 271 (03) :655-663
[24]   Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program [J].
Skaane, Per ;
Bandos, Andriy I. ;
Gullien, Randi ;
Eben, Ellen B. ;
Ekseth, Ulrika ;
Haakenaasen, Unni ;
Izadi, Mina ;
Jebsen, Ingvild N. ;
Jahr, Gunnar ;
Krager, Mona ;
Niklason, Loren T. ;
Hofvind, Solveig ;
Gur, David .
RADIOLOGY, 2013, 267 (01) :47-56
[25]   Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A Comparison [J].
Spangler, M. Lee ;
Zuley, Margarita L. ;
Sumkin, Jules H. ;
Abrams, Gordan ;
Ganott, Marie A. ;
Hakim, Christiane ;
Perrin, Ronald ;
Chough, Denise M. ;
Shah, Ratan ;
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) :320-324
[26]   Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography [J].
Svahn, T. M. ;
Houssami, N. ;
Sechopoulos, I. ;
Mattsson, S. .
BREAST, 2015, 24 (02) :93-99
[27]   Digital Breast Tomosynthesis Might Not Be the Optimal Modality for Detecting Microcalcification [J].
Tagliafico, Alberto ;
Houssami, Nehmat .
RADIOLOGY, 2015, 275 (02) :618-619
[28]   Characterisation of microcalcification clusters on 2D digital mammography (FFDM) and digital breast tomosynthesis (DBT): does DBT underestimate microcalcification clusters? Results of a multicentre study [J].
Tagliafico, Alberto ;
Mariscotti, Giovanna ;
Durando, Manuela ;
Stevanin, Carmen ;
Tagliafico, Giulio ;
Martino, Lucia ;
Bignotti, Bianca ;
Calabrese, Massimo ;
Houssami, Nehmat .
EUROPEAN RADIOLOGY, 2015, 25 (01) :9-14
[29]   Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study [J].
Timberg, P. ;
Bath, M. ;
Andersson, I. ;
Mattsson, S. ;
Tingberg, A. ;
Ruschin, M. .
MEDICAL PHYSICS, 2012, 39 (05) :2431-2437
[30]   Intermediate to highly suspicious calcification in breast lesions: a radio-pathologic correlation [J].
Tse, Gary M. ;
Tan, Puay-Hoon ;
Cheung, Humairah S. ;
Chu, Winnie C. W. ;
Lam, Wynnie W. M. .
BREAST CANCER RESEARCH AND TREATMENT, 2008, 110 (01) :1-7