Fiber loop ring-down cavity integrated U-bent single-mode-fiber for magnetic field sensing

被引:38
作者
Chen, Yaofei [1 ,2 ]
Liu, Tiegen [1 ,3 ]
Han, Qun [1 ]
Yan, Wenchuan [1 ]
Yu, Lin [1 ]
机构
[1] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[3] Tianjin Univ, Minist Educ, Key Lab Optoelect Informat Technol, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
REFRACTIVE-INDEX SENSOR; INTERFEROMETER; SPECTROSCOPY; FLUID;
D O I
10.1364/PRJ.4.000322
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel magnetic field sensing system based on the fiber loop ring-down technique is proposed in this paper. In the fiber loop, a U-bent single-mode-fiber structure coated with magnetic fluid (MF) serves as the sensing head, and an erbium-doped fiber amplifier (EDFA) is introduced to compensate for the intrinsic loss of the cavity. The ring-down time of the system varies with the change of applied magnetic field due to the tunable absorption coefficient and refractive index of the MF. Therefore, measurement of the magnetic field can be realized by monitoring the ring-down time. The experimental results show that the performance of the system is extremely dependent on the interrogation wavelength, because both the gain of the EDFA and the loss of the sensing head are wavelength dependent. We found that at the optimal wavelength, the ratio of the gain to loss attained its maximum. The sensing system was experimentally demonstrated and a sensitivity of -0.5951 mu s/Oe was achieved. (C) 2016 Chinese Laser Press
引用
收藏
页码:322 / 326
页数:5
相关论文
共 20 条
[1]   A simple single-mode fiber loss measurement scheme in the C-band based on fiber loop-cavity ringdown spectroscopy [J].
Berberoglu, Halil ;
Altan, Hakan .
OPTICS COMMUNICATIONS, 2014, 317 :29-33
[2]   Optical fiber magnetic field sensor based on single-mode-multimode-single-mode structure and magnetic fluid [J].
Chen, Yaofei ;
Han, Qun ;
Liu, Tiegen ;
Lan, Xinwei ;
Xiao, Hai .
OPTICS LETTERS, 2013, 38 (20) :3999-4001
[3]   Magnetic field sensor based on anti-resonant reflecting guidance in the magnetic gel-coated hollow core fiber [J].
Gao, R. ;
Jiang, Y. ;
Zhao, Yang .
OPTICS LETTERS, 2014, 39 (21) :6293-6296
[4]   Investigation on an evanescent wave fiber-optic absorption sensor based on fiber loop cavity ring-down spectroscopy [J].
Jiang Meng ;
Zhang Weigang ;
Zhang Qi ;
Liu Yaping ;
Liu Bo .
OPTICS COMMUNICATIONS, 2010, 283 (02) :249-253
[5]   Magnetic Field Sensor Based on U-Bent Single-Mode Fiber and Magnetic Fluid [J].
Liu, Tiegen ;
Chen, Yaofei ;
Han, Qun ;
Lu, Xiaoying .
IEEE PHOTONICS JOURNAL, 2014, 6 (06)
[6]   Fiber cavity ring-down refractive index sensor [J].
Ni, N. ;
Chan, C. C. ;
Xia, L. ;
Shum, P. .
IEEE PHOTONICS TECHNOLOGY LETTERS, 2008, 20 (13-16) :1351-1353
[7]   Cavity ring-down long period grating pressure sensor [J].
Ni, N. ;
Chan, C. C. ;
Wong, W. C. ;
Shao, L. Y. ;
Dong, X. Y. ;
Shum, P. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 158 (02) :207-211
[8]   Magnetic field sensor using the fiber loop ring-down technique and an etched fiber coated with magnetic fluid [J].
Shen, Tao ;
Feng, Yue ;
Sun, Binchao ;
Wei, Xinlao .
APPLIED OPTICS, 2016, 55 (04) :673-678
[9]  
Shengli P., 2014, IEEE PHOTONICS J, V6
[10]   Cavity-enhanced spectroscopy in fiber cavities [J].
Stewart, G ;
Atherton, K ;
Culshaw, B .
OPTICS LETTERS, 2004, 29 (05) :442-444