Comparison of portable oxygen concentrators in a simulated airplane environment

被引:14
作者
Fischer, Rainald [1 ]
Wanka, Eva R. [1 ,2 ,3 ]
Einhaeupl, Franziska [1 ]
Voll, Klaus [4 ]
Schiffl, Helmut [5 ]
Lang, Susanne M. [5 ]
Gruss, Martin [6 ]
Ferrari, Uta [1 ]
机构
[1] Univ Hosp Munich, Med Klin & Poliklin 5, D-80336 Munich, Germany
[2] Univ Hosp Munich, Inst & Outpatient Clin Occupat Social & Environm, D-80336 Munich, Germany
[3] Univ Hosp Munich, Inst Emergency Med & Management Med, D-80336 Munich, Germany
[4] EMS Ltd, Mohrendorf, Germany
[5] SRH Wald Klinikum Gera, Med Klin 2, Gera, Germany
[6] Air Be C Ltd, Gera, Germany
关键词
Altitude; Airplane; Travel; COPD;
D O I
10.1016/j.rmed.2012.10.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Portable oxygen concentrators (POC) are highly desirable for patients with lung disease traveling by airplane, as these devices allow theoretically much higher travel times if additional batteries can be used. However, it is unclear whether POCs produce enough oxygen in airplanes at cruising altitude, even if complying with aviation regulations. We evaluated five frequently used POCs (XPO2 (Invacare, USA), Freestyle (AirSep C., USA), Evergo (Philipps Healthcare, Germany), Inogen One (Inogen, USA), Eclipse 3 (Sequal, USA)) at an altitude of 2650 m (as simulated airplane environment) in 11 patients with chronic obstructive lung disease (COPD) and compared theses POCs with the standard oxygen system (WS120, EMS Ltd., Germany) used by Lufthansa. Oxygen was delivered by each POC for 30 min to each patient at rest, blood gases were then drawn from the arterialized ear lobe. All POCs were able to deliver enough oxygen to increase the PaO2 of our subjects by at least 1.40 kPa (10 mmHg). However, to achieve this increase, the two most lightweight POCs (Freestyle and Invacare XP02) had to be run at their maximum level. This causes a significant reduction of battery life. The three other POCs (Ever Go, Inogen One, Eclipse 3) and the WS120 were able to increase the PaO2 by more than 2.55 kPa (20 mmHg), which provides extra safety for patients with more severe basal hypoxemia. When choosing the right oxygen system for air travel in patients in COPD, not only weight, but also battery life and maximum possible oxygen output must be considered carefully. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 149
页数:3
相关论文
共 6 条
[1]   Managing passengers with stable respiratory disease planning air travel: British Thoracic Society recommendations [J].
Ahmedzai, S. ;
Balfour-Lynn, I. M. ;
Bewick, T. ;
Buchdahl, R. ;
Coker, R. K. ;
Cummin, A. R. ;
Gradwell, D. P. ;
Howard, L. ;
Innes, J. A. ;
Johnson, A. O. C. ;
Lim, E. ;
Lim, Wei Shen ;
McKinlay, K. P. ;
Partridge, M. R. ;
Popplestone, M. ;
Pozniak, A. ;
Robson, A. ;
Shovlin, C. L. ;
Shrikrishna, D. ;
Simonds, A. ;
Tait, P. ;
Thomas, M. .
THORAX, 2011, 66 :1-30
[2]   COPD and Air Travel Oxygen Equipment and Preflight Titration of Supplemental Oxygen [J].
Akero, Aina ;
Edvardsen, Anne ;
Christensen, Carl C. ;
Owe, Jan O. ;
Ryg, Morten ;
Skjonsberg, Ole H. .
CHEST, 2011, 140 (01) :84-90
[3]  
Department of Transportation (DOT), 2012, FIN RUL NOND BAS DIS
[4]  
European Lung Foundation, 2010, DAT OX POL MAN AIRL
[5]   Lung function in adults with cystic fibrosis at altitude:: impact on air travel [J].
Fischer, R ;
Lang, SM ;
Brückner, K ;
Hoyer, HX ;
Meyer, S ;
Griese, M ;
Huber, RM .
EUROPEAN RESPIRATORY JOURNAL, 2005, 25 (04) :718-724
[6]   ARTERIALIZED EAR LOBE BLOOD-SAMPLES FOR BLOOD-GAS TENSIONS [J].
SPIRO, SG ;
DOWDESWELL, IRG .
BRITISH JOURNAL OF DISEASES OF THE CHEST, 1976, 70 (04) :263-268