A preliminary study of deep learning-based reconstruction specialized for denoising in high-frequency domain: usefulness in high-resolution three-dimensional magnetic resonance cisternography of the cerebellopontine angle

被引:26
作者
Uetani, Hiroyuki [1 ]
Nakaura, Takeshi [1 ]
Kitajima, Mika [1 ]
Yamashita, Yuichi [2 ]
Hamasaki, Tadashi [3 ]
Tateishi, Machiko [1 ]
Morita, Kosuke [4 ]
Sasao, Akira [1 ]
Oda, Seitaro [1 ]
Ikeda, Osamu [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, Chuo Ku, 1-1-1 Honjo, Kumamoto, Japan
[2] Canon Med Syst Corp, MRI Sales Dept, Sales Engineer Grp, Saiwai Ku, 70-1 Yanagi Cho, Kawasaki, Kanagawa 2120015, Japan
[3] Kumamoto Univ, Dept Diagnost, Neurosurg, Fac Life Sci,Chuo Ku, 1-1-1 Honjo, Kumamoto, Japan
[4] Kumamoto Univ Hosp, Dept Radiol, Chuo Ku, 1-1-1 Honjo, Kumamoto, Japan
关键词
Deep learning; Image reconstruction; Magnetic resonance imaging; Noise; Signal-to-noise ratio; SPIN-ECHO; MRI; NERVE;
D O I
10.1007/s00234-020-02513-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Deep learning-based reconstruction (DLR) has been developed to reduce image noise and increase the signal-to-noise ratio (SNR). We aimed to evaluate the efficacy of DLR for high spatial resolution (HR)-MR cisternography. Methods This retrospective study included 35 patients who underwent HR-MR cisternography. The images were reconstructed with or without DLR. The SNRs of the CSF and pons, contrast of the CSF and pons, and sharpness of the normal-side trigeminal nerve using full width at half maximum (FWHM) were compared between the two image types. Noise quality, sharpness, artifacts, and overall image quality of these two types of images were qualitatively scored. Results The SNRs of the CSF and pons were significantly higher with DLR than without DLR (CSF 21.81 +/- 7.60 vs. 15.33 +/- 4.03,p < 0.001; pons 5.96 +/- 1.38 vs. 3.99 +/- 0.48,p < 0.001). There were no significant differences in the contrast of the CSF and pons (p = 0.225) and sharpness of the normal-side trigeminal nerve using FWHM (p = 0.185) without and with DLR, respectively. Noise quality and the overall image quality were significantly higher with DLR than without DLR (noise quality 3.95 +/- 0.19 vs. 2.53 +/- 0.44,p < 0.001; overall image quality 3.97 +/- 0.17 vs. 2.97 +/- 0.12,p < 0.001). There were no significant differences in sharpness (p = 0.371) and artifacts (p = 1) without and with DLR. Conclusion DLR can improve the image quality of HR-MR cisternography by reducing image noise without sacrificing contrast or sharpness.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 29 条
[11]   Deep Learning Based Noise Reduction for Brain MR Imaging: Tests on Phantoms and Healthy Volunteers [J].
Kidoh, Masafumi ;
Shinoda, Kensuke ;
Kitajima, Mika ;
Isogawa, Kenzo ;
Nambu, Masahito ;
Uetani, Hiroyuki ;
Morita, Kosuke ;
Nakaura, Takeshi ;
Tateishi, Machiko ;
Yamashita, Yuichi ;
Yamashita, Yasuyuki .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (03) :195-206
[12]   Wavelets in temporal and spatial processing of biomedical images [J].
Laine, AF .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2000, 2 :511-550
[13]   Deep Learning for Automated Contouring of Primary Tumor Volumes by MRI for Nasopharyngeal Carcinoma [J].
Lin, Li ;
Dou, Qi ;
Jin, Yue-Ming ;
Zhou, Guan-Qun ;
Tang, Yi-Qiang ;
Chen, Wei-Lin ;
Su, Bao-An ;
Liu, Feng ;
Tao, Chang-Juan ;
Jiang, Ning ;
Li, Jun-Yun ;
Tang, Ling-Long ;
Xie, Chuan-Miao ;
Huang, Shao-Min ;
Ma, Jun ;
Heng, Pheng-Ann ;
Wee, Joseph T. S. ;
Chua, Melvin L. K. ;
Chen, Hao ;
Sun, Ying .
RADIOLOGY, 2019, 291 (03) :677-686
[14]  
Liu Ping, 2003, Magn Reson Med Sci, V2, P109, DOI 10.2463/mrms.2.109
[15]   Usefulness of Subtraction of 3D T2WI-DRIVE from Contrast-Enhanced 3D T1WI: Preoperative Evaluations of the Neurovascular Anatomy of Patients with Neurovascular Compression Syndrome [J].
Masuda, Y. ;
Yamamoto, T. ;
Akutsu, H. ;
Shiigai, M. ;
Masumoto, T. ;
Ishikawa, E. ;
Matsuda, M. ;
Matsumura, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) :317-322
[16]   Magnetic Resonance Imaging of the Brain Using Compressed Sensing - Quality Assessment in Daily Clinical Routine [J].
Moench, Sebastian ;
Sollmann, Nico ;
Hock, Andreas ;
Zimmer, Claus ;
Kirschke, Jan S. ;
Hedderich, Dennis M. .
CLINICAL NEURORADIOLOGY, 2020, 30 (02) :279-286
[17]  
Naganawa S, 2001, AM J NEURORADIOL, V22, P1179
[18]   Does the location of a vascular loop in the cerebellopontine angle explain pulsatile and non-pulsatile tinnitus? [J].
Nowé, V ;
De Ridder, D ;
Van de Heyning, PH ;
Wang, XL ;
Gielen, J ;
Goethem, J ;
Özsarlak, Ö ;
De Schepper, AM ;
Parizel, PM .
EUROPEAN RADIOLOGY, 2004, 14 (12) :2282-2289
[19]   Clinical Evaluation of a Multiparametric Deep Learning Model for Glioblastoma Segmentation Using Heterogeneous Magnetic Resonance Imaging Data From Clinical Routine [J].
Perkuhn, Michael ;
Stavrinou, Pantelis ;
Thiele, Frank ;
Shakirin, Georgy ;
Mohan, Manoj ;
Garmpis, Dionysios ;
Kabbasch, Christoph ;
Borggrefe, Jan .
INVESTIGATIVE RADIOLOGY, 2018, 53 (11) :647-654
[20]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO